Submit an Article
Become a reviewer

Search articles for by keywords:
purification

Geotechnical Engineering and Engineering Geology
  • Date submitted
    2024-04-11
  • Date accepted
    2024-06-03
  • Date published
    2024-07-04

Assessment of the efficiency of acid mine drainage purification (using the example of copper-pyrite mines in the Middle Urals)

Article preview

According to the results of the anti-rating of regions with extreme pollution of watercourses in the Sverdlovsk region, the largest number of polluted rivers has been recorded in recent years – more than a quarter of all high and extremely high pollution. One of the sources of pollution of natural water bodies in the Middle Urals are closed and flooded copper-pyrite mines, where acidic mine drainage continue to form and unload to the surface. Several of them have organized collection and a two-stage acidic drainage purification system, including neutralization with lime milk and settling in a clarifier pond. Despite the identical schemes, different indicators of pollutants are recorded during discharge into water bodies. The aim of the work is to evaluate the effectiveness of the applied acid mine drainage purification system and identify the parameters affecting the quality of treated mine water. Laboratory studies were performed using methods of flame emission spectrometry, flame atomic absorption, atomic absorption spectrometry, mass spectrometry with ionization in inductively coupled plasma, potentiometric, etc. It has been established that the existing mine drainage purification system at the Degtyarskii mine makes it possible to significantly reduce the concentrations of most toxic components of mine waters to almost standard values. At the Levikhinskii mine, the multiplicity of exceeding the maximum permissible concentrations reaches hundreds and thousands of times. To achieve a higher degree of purification, it is necessary that the duration of passive purification is sufficient for the reactant to interact with acidic waters. However, to ensure this possibility, it will require the creation of a cascade of ponds with an area of several thousand hectares. If the current two-stage system is quite effective for the Degtyarskii mine, then for Levikhinskii it is necessary to switch to the use of more modern systems, including three stages of purification.

How to cite: Rybnikova L.S., Rybnikov P.A., Navolokina V.Y. Assessment of the efficiency of acid mine drainage purification (using the example of copper-pyrite mines in the Middle Urals) // Journal of Mining Institute. 2024. Vol. 267. p. 388-401. EDN SBKRCK
Geotechnical Engineering and Engineering Geology
  • Date submitted
    2024-03-30
  • Date accepted
    2024-06-03
  • Date published
    2024-07-04

Preparation and use of complex titanium-containing coagulant from quartz-leucoxene concentrate

Article preview

The search for the new high-efficiency reagents for wastewater treatment is a challenging and urgent task. Titanium-containing coagulants represent a new trend in water treatment and have a much higher efficiency that the traditional aluminium and iron-containing coagulants. The high cost of reagents significantly hinders their implementation. Complex titanium-containing reagents are coagulants prepared by modifying the traditional coagulants by adding 2.5-10.0 wt.% titanium compounds. In this work, titanium tetrachloride prepared from quartz-leucoxene concentrate was prehydrolyzed with subsequent double decomposition with sulfuric acid. The resulting mixture of hydrochloric and sulfuric acids was neutralized with aluminium hydroxide/oxide to form a self-hardening mixture (chemical dehydration). The sample of a complex sulfate-chloride titanium-containing coagulant was a mixture of AlCl3·6H2O – 5-20 wt.%, Al2(SO4)3·18H2O – 70-90 wt.% and TiOSO4 – 2.5-10.0 wt.%. It was proved that by changing the ratio of aluminium oxide/hydroxide and titanium tetrachloride at the stage of prehydrolysis and double decomposition, it is possible to obtain samples of a complex coagulant with different contents of the modifying additive of titanium compounds. An assessment of the coagulation properties of the complex reagent demonstrated its higher efficiency in cold water compared to aluminium sulfate. Studies on the use of the complex titanium-containing coagulant in the process of wastewater treatment from phosphate anions and suspended matter demonstrated its higher efficiency as compared to that of traditional reagents. The advantages of the prepared reagent are a reduction in the effective dose of the reagent, minimization of residual concentrations of pollutants in purified water, intensification of the processes of sedimentation and filtration of coagulation sludge. Purified water can be reused in the recycling water supply system. The use of quartz-leucoxene concentrate and titanium tetrachloride obtained from it as the source material would not only minimize the cost of the resulting complex coagulant, but also take a step towards the implementation of the Zero Waste concept.

How to cite: Kuzin E.N. Preparation and use of complex titanium-containing coagulant from quartz-leucoxene concentrate // Journal of Mining Institute. 2024. Vol. 267. p. 413-420. EDN LQQWFL
Geotechnical Engineering and Engineering Geology
  • Date submitted
    2024-04-25
  • Date accepted
    2024-06-13
  • Date published
    2024-07-11

Evaluation of the effectiveness of neutralization and purification of acidic waters from metals with ash when using alternative fuels from municipal waste

Article preview

The problem of pollution of natural water objects with heavy metals is extremely relevant for the areas where industrial enterprises are located. Unauthorized discharge of contaminated wastewater, inefficient operation of sewage treatment plants, as well as leakage of drainage waters from man-made massifs lead to changes in the hydrological system affecting living objects. The article studies the composition of ash from the combustion of alternative fuels from municipal waste, and also considers the possibility of using it to neutralize sulfuric acid drainage waters and extract metal ions (Cu, Cd, Fe, Mn, Zn) from them. It has been established that the efficiency of water purification from metals depends on the pH value achieved during the purification process. The pH value is regulated by the dose of the introduced ash, the contact time and depends on the initial concentration of metal ions and sulfates in the solution. Studies on the neutralization and purification of a model solution of sulfuric acid drainage waters of a tailings farm of known composition have shown that in order to achieve a pH of 8-9, optimal for precipitation of metal hydroxides Cu, Cd, Fe, Mn, Zn and Al washed out of ash, and water purification with an efficiency of 96.60 to 99.99 %, it is necessary to add 15 g/l of ash and stir the suspension continuously for 35 minutes. It was revealed that exposure to ash with sulfuric acid waters leads to the transition of water-soluble forms of metals into insoluble ones and their “cementation” with calcium sulfate. The amount of Zn and Fe ions washed out of the ash decreases by 82 and 77 %, Al, Cd, Cu, Mn – by 25 %. This reduces the toxicity of ash, which is proved by a decrease in the toxic multiplicity of dilution of the water extract by 14 times.

How to cite: Kharko P.A., Danilov A.S. Evaluation of the effectiveness of neutralization and purification of acidic waters from metals with ash when using alternative fuels from municipal waste // Journal of Mining Institute. 2024. p. EDN CGGRHJ
Geotechnical Engineering and Engineering Geology
  • Date submitted
    2022-10-23
  • Date accepted
    2023-02-13
  • Date published
    2023-12-25

Sorption purification of acid storage facility water from iron and titanium on organic polymeric materials

Article preview

Obtaining and production of metals from natural raw materials causes a large amount of liquid, solid, and gaseous wastes of various hazard classes that have a negative impact on the environment. In the production of titanium dioxide from ilmenite concentrate, hydrolytic sulphuric acid is formed, which includes various metal cations, their main part is iron (III) and titanium (IV) cations. Hydrolytic acid waste is sent to acid storage facilities, which have a high environmental load. The article describes the technology of ion exchange wastewater treatment of acid storage facility from iron (III) and titanium (IV) cations, which form compounds with sulphate ions and components of organic waste in acidic environments. These compounds are subjected to dispersion and dust loss during the evaporation of a water technogenic facility, especially in summer season. Sorption of complex iron (III) cations [FeSO4]+ and titanyl cations TiO2+ from sulphuric acid solutions on cation exchange resins KU-2-8, Puromet MTS9580, and Puromet MTS9560 was studied. Sorption isotherms were obtained both for individual [FeSO4]+ and TiO2+ cations and in the joint presence. The values of the equilibrium constants at a temperature of 298 K and the changes in the Gibbs energy are estimated. The capacitive characteristics of the sorbent were determined for individual cations and in the joint presence.

How to cite: Cheremisina O.V., Ponomareva M.A., Molotilova A.Y., Mashukova Y.A., Soloviev M.A. Sorption purification of acid storage facility water from iron and titanium on organic polymeric materials // Journal of Mining Institute. 2023. Vol. 264. p. 971-980. DOI: 10.31897/PMI.2023.28
Geotechnical Engineering and Engineering Geology
  • Date submitted
    2021-10-08
  • Date accepted
    2022-01-24
  • Date published
    2022-04-29

Methodology for thermal desorption treatment of local soil pollution by oil products at the facilities of the mineral resource industry

Article preview

The analysis of the main environmental consequences of leaks and local spills of petroleum products at the enterprises of the mineral resource complex is presented. It is established that the problem of soil contamination with petroleum products at the facilities of the mineral resource complex and enterprises of other industries is caused by significant volumes of consumption of the main types of oil products. Based on the results of the author's previous field research, a series of experiments was carried out, consisting in modeling artificial soil pollution with petroleum products such as gasoline, diesel fuel, highly refined oil, motor oil, and transmission oil, followed by their purification by heat treatment at temperatures of 150, 200, and 250 °C. The 250 °C limit of the heating temperature was set due to the need to partially preserve the structure and quality of the soil after heat treatment to preserve its fertility. When the processing temperature rises to 450 °C, all humates are completely burned out and, as a result, productivity is lost. Confirmation is provided by the results of experiments to determine the humus content in uncontaminated soil and soil treated at different temperatures. It was found that at a maximum processing temperature of 250 °C, about 50 % of the initial organic carbon content is preserved. According to the results of the conducted experimental studies, the dependences of the required processing temperature on the concentration of petroleum products to reduce the concentration of petroleum products to an acceptable level have been established. The methodology of thermal desorption cleaning of soils with varying degrees of contamination at enterprises of the mineral resource complex is presented.

How to cite: Pashkevich M.A., Bykova M.V. Methodology for thermal desorption treatment of local soil pollution by oil products at the facilities of the mineral resource industry // Journal of Mining Institute. 2022. Vol. 253. p. 49-60. DOI: 10.31897/PMI.2022.6
Geoecology and occupational health and safety
  • Date submitted
    2015-08-17
  • Date accepted
    2015-10-25
  • Date published
    2016-04-22

Ecological aspects of vehicle tunnels ventilation in the conditions of megalopolises

Article preview

The characteristic of Russia and foreign vehicle tunnels are provided in paper and advantages of their placement in the conditions of the city are noted. It is shown that one of the main factors defining negative impact on environment in the period of tunnels driving is mine equipment, and at operation – vehicles. The analysis of essential differences of features of pollution of atmospheric air at construction of tunnels from its pollution at construction of buildings on a surface is given. The examples illustrating levels of negative impact of the upcast ventilation shaft airflow on atmospheric air are given and the ventilation schemes reducing this influence are offered. It is shown that during operation of road tunnels of pollution of the air environment can extend on considerable distances from tunnel portals. Numerical calculations of concentration of carbon oxides and nitrogen during removal of the upcast ventilation shaft airflow through portals and through the mines built near them are executed. Technical solutions on purifications of tunnel air by means of electrostatic filters are described.

How to cite: Gendler S.G. Ecological aspects of vehicle tunnels ventilation in the conditions of megalopolises // Journal of Mining Institute. 2016. Vol. 218. p. 313-321.