Date submitted2024-04-11
-
Date accepted2024-11-07
-
Date published2025-01-17
Thyristor booster device for voltage fluctuation reduction in power supply systems of ore mining enterprises
The article is devoted to solving the problem of voltage fluctuations in the power supply systems of ore mining enterprises. The connection of high-power consumers with abruptly variable operating mode (for example, high-voltage mining excavators) causes voltage fluctuations and sags, disabling electrical equipment, communication, and automation devices in the 6-10 kV distribution network, which disrupts technological processes, etc. The use of existing solutions and methods to reduce voltage variations caused by dynamic loads is not effective. To solve the problem, booster transformers with high-speed thyristor switches can be used to work out switching the control steps towards increasing or decreasing the voltage. The authors offer a new circuitry solution for a thyristor booster device (TBD) with a pulse-phase control method. The purpose of the research is to determine the control laws of TBD, which enable to effectively reduce voltage fluctuations from dynamic load in the power supply systems of mining enterprises. The article provides a schematic diagram of the TBD and describes the principle of operation of the device. Some modes of increasing and decreasing the output voltage of the TBD, as well as the basic mode (without voltage addition) are provided. Mathematical modeling of TBD control processes was carried out and adjustment characteristics were set taking into account the load power factor. On a simulation computer model of a 6 kV electric network with a dynamic load, the verification of the adjustment characteristics of TBD obtained during mathematical modeling was carried out. Based on the research results, the laws for regulating the output voltage of TBD were established. The TBD effective control range with normal permissible limits of odd harmonics have been determined. The conducted research will make it possible to implement the device control system.
-
Date submitted2022-09-05
-
Date accepted2023-09-20
-
Date published2024-04-25
Modeling the efficiency of seasonal cooling devices when changing the statistical distribution of weather conditions
The climatic factor of warming, which is evidenced by a significant number of scientists and research teams in Russia and the world, has a significant impact on the cryogenic state of permafrost soil, the preservation of which is one of the most common principles of construction in the North. The influence of projected climatic changes in planning up to 2050 on the efficiency of seasonal cooling devices, the principle of operation of which is based on seasonal soil freezing, is considered. The conducted modeling has shown that in a situation of stable climate, the preservation of the cryogenic state of permafrost soil is realized without the use of additional measures. With warming with a trend of 0.1 °C per year, seasonal cooling devices do not ensure the preservation of the current level of the cryogenic state of the soil and additional measures are required to increase their efficiency in the summer. In the case of more extreme warming with a rate of 0.25 °C per year, the modeling results show that seasonal cooling devices do not significantly affect the rate of soil thawing and the solution to the problem should be its complete replacement with systems with year-round action.
-
Date submitted2021-10-19
-
Date accepted2021-11-30
-
Date published2021-12-27
Potential technological solution for sampling the bottom sediments of the subglacial lake Vostok: relevance and formulation of investigation goals
The subglacial Lake Vostok in Antarctic is a unique natural phenomenon, its comprehensive study involves sampling of water and bottom surface rocks. For further study of the lake, it is necessary to drill a new access well and develop environmentally safe technologies for its exploration. This article discusses existing and potential technologies for sampling bottom surface rocks of subglacial lakes. All these technologies meet environmental safety requirements and are conducive for sampling. The authors have proposed an alternative technology, using a walking device, which, due to its mobility, enables selective sampling of rocks across a large area from a single access well. The principal issues, related to the implementation of the proposed technology, are investigated within this article. This report is prepared by a team of specialists with many years of experience in drilling at the Vostok Station in Antarctic and in experimental work on the design of equipment and non-standard means of mechanization for complicated mining, geological and climatic conditions.
-
Date submitted2020-07-02
-
Date accepted2021-02-16
-
Date published2021-04-26
Development of viscoelastic systems and technologies for isolating water-bearing horizons with abnormal formation pressures during oil and gas wells drilling
Article provides a brief overview of the complications arising during the construction of oil and gas wells in conditions of abnormally high and abnormally low formation pressures. Technological properties of the solutions used to eliminate emergency situations when drilling wells in the intervals of catastrophic absorption and influx of formation fluid have been investigated. A technology for isolating water influx in intervals of excess formation pressure has been developed. The technology is based on the use of a special device that provides control of the hydrodynamic pressure in the annular space of the well. An experiment was carried out to determine the injection time of a viscoelastic system depending on its rheology, rock properties and technological parameters of the isolation process. A mathematical model based on the use of a special device is presented. The model allows determining the penetration depth of a viscoelastic system to block water-bearing horizons to prevent interformation crossflows and water breakthrough into production wells.
-
Date submitted2019-04-28
-
Date accepted2019-06-28
-
Date published2019-10-23
Determination of Optimal Fluorine Leaching Parameters from the Coal Part of the Waste Lining of Dismantled Electrolytic Cells for Aluminum Production
- Authors:
- N. V. Nemchinova
- A. A. Tyutrin
- V. V. Somov
When aluminum is obtained by electrolysis of cryolite-alumina melts when the baths are sent for capital repairs, a solid technogenic product is formed – waste lining of electrolytic cells (WLEC). The volume of formation of WLEC is 30-50 kg per 1 ton of aluminum. Currently, it is mainly stored at landfills near industrial enterprises, causing harm to the environment. However, this technogenic raw material contains valuable components (fluorine, aluminum, sodium) that can be extracted to produce fluoride salts, which are in demand during the electrolytic production of aluminum. The objects of research were samples of the coal part of the waste lining of dismantled S-8BM (E) type electrolytic cells of «RUSAL Krasnoyarsk» JSC (Krasnoyarsk) of RUSAL company. According to the X-ray experiment diffraction analysis (using a Bruker D8 ADVANCE diffractometer) of the phase composition of the samples, it was found that the main fluorine-containing compounds are cryolite, chiolite, sodium and calcium fluorides. The total fluorine content in the studied samples averaged 13.1 %. We conducted studies on the leaching of fluorine from WLEC with a solution of caustic alkali (NaOH concentration – 17.5 g/dm 3 ). The process was carried out in a mechanically agitated reactor using a BIOSAN MM-1000 top drive laboratory stirrer with a two-blade nozzle. By the method of mathematical planning of a three-factor experiment, the mutual influence of three leaching conditions on the optimization parameter was established – the extraction of fluorine in solution (in percent). The maximum recovery of fluorine from WLEC to the leach solution averaged 86.4 % and was achieved with the following indicators:processtemperature–95 ° C, the ratio ofliquidtosolidphase–9:1,duration– 210 min.
-
Date submitted2015-12-10
-
Date accepted2016-02-18
-
Date published2016-12-23
Engineering and technical measures to improve reliability of power supply to construction facilities
- Authors:
- P. S. Orlov
The paper examines an issue of ensuring reliable power supply to construction facilities, proposes ways to reduce losses in distribution networks and improve power supply reliability. The primary focus is on increasing the transmission capability of power distribution networks and improving power supply reliability and safety of single-phase electricity consumers. Engineering and technical proposal belongs to the field of electrical engineering and in particular concerns power supply to single-phase consumers from three-phase networks, including construction industry consumers, and can be used in three-phase three-, four- and five-wives alternating current power distribution networks.