Submit an Article
Become a reviewer
JOURNAL IMPACT FACTOR
2.8
WEB OF SCIENCE
citescore
9.0
scopus

Vol 84

Previous
Vol 81
Article
  • Date submitted
    1978-08-27
  • Date accepted
    1978-10-09
  • Date published
    1979-02-01

On the evaluation of voltage quality in distribution networks of potash mines

Article preview

Improving the efficiency of potash mines is associated with the improvement of all links of the technological process of potash ore mining and, first of all, with ensuring uninterrupted and reliable operation of mining and transportation machines, the stable and highly productive operation of which depends on the quality of electrical energy in the hoisting distribution network. ...

How to cite: Konovalov B.P., Shklyarsky Y.E., Smirnova L.N. On the evaluation of voltage quality in distribution networks of potash mines // Journal of Mining Institute. 1979. Vol. 84. p. 3-9.
Article
  • Date submitted
    1978-08-23
  • Date accepted
    1978-10-09
  • Date published
    1979-02-01

Experience in the industrial operation of UPC in 6 kV distribution networks of potash mines

Article preview

The low voltage quality in the load supply centers of mining sections during normal operation of the distribution network required operating measures to improve it. An effective means of reducing voltage losses in a 6 kV network under the conditions of potash mines is the use of longitudinal-capacitive voltage loss compensation installations.…

How to cite: Ivanov O.V., Konovalov B.P., Malyushitsky M.M., Ryzhkov V.D. Experience in the industrial operation of UPC in 6 kV distribution networks of potash mines // Journal of Mining Institute. 1979. Vol. 84. p. 10-12.
Article
  • Date submitted
    1978-08-30
  • Date accepted
    1978-10-17
  • Date published
    1979-02-01

Calculation methodology of distribution networks of mining enterprises with compensating devices for voltage and reactive power losses

Article preview

The distribution network of potash mines is characterized by great length and energy intensity. Therefore, the voltage value in remote sections of the network often reaches values unacceptable under GOST. To compensate for voltage losses in the distribution networks of potash mines, the following devices can be used: booster transformers BDT; series capacitors SC; parallel sources of reactive power. …

How to cite: Ivanov O.V., Proskuryakov E.M., Smirnova L.N. Calculation methodology of distribution networks of mining enterprises with compensating devices for voltage and reactive power losses // Journal of Mining Institute. 1979. Vol. 84. p. 13-19.
Article
  • Date submitted
    1978-08-21
  • Date accepted
    1978-10-29
  • Date published
    1979-02-01

Methodology for calculating operating modes of UPC with a thyristor arrester during short circuits in 6 kV distribution networks

Article preview

Protection of UPC longitudinal compensation units from overvoltages during short circuits in the 6 kV network can be implemented by means of a thyristor arrester connected in parallel with the capacitors of UPC. …

How to cite: Ivanov O.V., Maksimov S.A., Proskuryakov E.M. Methodology for calculating operating modes of UPC with a thyristor arrester during short circuits in 6 kV distribution networks // Journal of Mining Institute. 1979. Vol. 84. p. 20-24.
Article
  • Date submitted
    1978-08-16
  • Date accepted
    1978-10-05
  • Date published
    1979-02-01

Approximate method for calculating operating modes with a nonlinear inductive shunt element

Article preview

A nonlinear inductive shunt can be used to protect UPC longitudinal-capacitive compensation units from overvoltages when the current in the circuit increases. A rigorous calculation of network operating modes with the installation of longitudinal UPC compensation in this case is quite a difficult task. .... ...

How to cite: Bauman V.G., Kvyatkovsky V.M., Maksimov S.A. Approximate method for calculating operating modes with a nonlinear inductive shunt element // Journal of Mining Institute. 1979. Vol. 84. p. 25-29.
Article
  • Date submitted
    1978-08-15
  • Date accepted
    1978-10-25
  • Date published
    1979-02-01

Features of longitudinal-transverse compensation of voltage and reactive power losses in mine distribution networks

Article preview

Distribution networks of potash mines are characterized by great length of outgoing 6 kV cable lines and high power of consumers, which causes voltage deviations at the terminals of electrical receivers over 10%. Sharply variable loads and frequent starts of high-power electric motors cause large voltage fluctuations. This leads to disruption of the normal operation of mechanisms and premature failure of electric motors.…

How to cite: Kvyatkovsky V.M., Proskuryakov E.M., Smirnova L.N., Shklyarsky Y.E. Features of longitudinal-transverse compensation of voltage and reactive power losses in mine distribution networks // Journal of Mining Institute. 1979. Vol. 84. p. 30-33.
Article
  • Date submitted
    1978-08-28
  • Date accepted
    1978-10-18
  • Date published
    1979-02-01

Analysis of mine distribution networks with longitudinal-transverse compensation

Article preview

Bearing in mind the expediency of longitudinal-transverse compensation in underground networks of potash mines, let us analyze the operating modes of the mine distribution network typical of the production association "Beloruskali." ...

How to cite: Kvyatkovsky V.M., Nefedova N.V., Shklyarsky Y.E. Analysis of mine distribution networks with longitudinal-transverse compensation // Journal of Mining Institute. 1979. Vol. 84. p. 34-39.
Article
  • Date submitted
    1978-08-04
  • Date accepted
    1978-10-17
  • Date published
    1979-02-01

Higher harmonics in UPC with a nonlinear inductive shunt element

Article preview

UPC longitudinal-capacitive compensation installations for preventing undesirable modes are sometimes expediently shunted by a nonlinear inductive element. ...

How to cite: Bauman V.G., Kvyatkovsky V.M., Maksimov S.A. Higher harmonics in UPC with a nonlinear inductive shunt element // Journal of Mining Institute. 1979. Vol. 84. p. 39-43.
Article
  • Date submitted
    1978-08-23
  • Date accepted
    1978-10-01
  • Date published
    1979-02-01

Influence of the inductance of the thyristor arrester power circuit on UPC modes during short circuits

Article preview

The inductance of the power circuit of the thyristor arrester, necessary for limiting the rate of rise of the forward current of thyristors, is very small and when calculating the operating modes of the UPC longitudinal compensation installation is usually not taken into account. ...

How to cite: Maksimov S.A. Influence of the inductance of the thyristor arrester power circuit on UPC modes during short circuits // Journal of Mining Institute. 1979. Vol. 84. p. 44-49.
Article
  • Date submitted
    1978-08-16
  • Date accepted
    1978-10-14
  • Date published
    1979-02-01

Formation on a physical model of loads statistically equivalent to real ones

Article preview

In the extended distribution network of a potash mine voltage loss reaches 10-15%, the operation of electric drives of mining and transportation machines in remote mining areas deteriorates. Improving the quality of electrical energy in the mine network involves the use of various compensating devices for voltage and reactive power losses. ...

How to cite: Konovalov B.P. Formation on a physical model of loads statistically equivalent to real ones // Journal of Mining Institute. 1979. Vol. 84. p. 50-56.
Article
  • Date submitted
    1978-08-07
  • Date accepted
    1978-10-04
  • Date published
    1979-02-01

Laboratory setup for reactive power regulation

Article preview

It is possible to reduce voltage and active power losses in the mine distribution network by simultaneous connection of longitudinal capacitive compensation units for voltage losses and unregulated reactive power sources. ...

How to cite: Nefedova N.V. Laboratory setup for reactive power regulation // Journal of Mining Institute. 1979. Vol. 84. p. 57-59.
Article
  • Date submitted
    1978-08-19
  • Date accepted
    1978-10-08
  • Date published
    1979-02-01

Electro-optical device for galvanic isolation device in voltage regulator circuits

Article preview

Existing thyristor circuits having a galvanic connection with the power part have a number of disadvantages: the possibility of undesirable thyristor triggering, the appearance of feedback, and the connection between low-voltage and high-voltage circuits. ...

How to cite: Ananyev K.A., Konovalova S.A., Nefedova N.V. Electro-optical device for galvanic isolation device in voltage regulator circuits // Journal of Mining Institute. 1979. Vol. 84. p. 60-63.
Article
  • Date submitted
    1978-08-12
  • Date accepted
    1978-10-26
  • Date published
    1979-02-01

Integrated protection of transformer substations of quarries against phase-to-ground faults

Article preview

Frequent operational switching in 6–10 kV quarry distribution networks changes their parameters over a wide range. This causes possible changes in the magnitudes of ground-fault currents on individual feeders and on the entire substation as a whole. ...

How to cite: Gansky V.P., Smirnov N.K. Integrated protection of transformer substations of quarries against phase-to-ground faults // Journal of Mining Institute. 1979. Vol. 84. p. 64-66.
Article
  • Date submitted
    1978-08-05
  • Date accepted
    1978-10-18
  • Date published
    1979-02-01

On the calculation of mine traction substations with pulse thyristor converters

Article preview

One of the directions in optimization of traction power supply parameters and the creation of modern automatic driving systems for mine trains is pulse thyristor converters. …

How to cite: Bannikov E.V., Stepanenko V.P., Chubarov L.A. On the calculation of mine traction substations with pulse thyristor converters // Journal of Mining Institute. 1979. Vol. 84. p. 67-72.
Article
  • Date submitted
    1978-08-17
  • Date accepted
    1978-10-11
  • Date published
    1979-02-01

Comparison of automatic driving systems for mine contact electric locomotives

Article preview

The method of automatic driving of contact electric locomotives without drivers is determined by the location of the devices regulating the voltage of traction motors and, consequently, by the speed of movement of the locomotive train.

How to cite: Bannikov E.V., Stepanenko V.P., Chubarov L.A. Comparison of automatic driving systems for mine contact electric locomotives // Journal of Mining Institute. 1979. Vol. 84. p. 73-77.
Article
  • Date submitted
    1978-08-10
  • Date accepted
    1978-10-29
  • Date published
    1979-02-01

Prospects of CPT3-I equipment for mine electric locomotives

Article preview

Automatic driving systems for mine contact electric locomotives are being developed mainly in two directions: the application of electric locomotives with a thyristor control system for traction motors; the use of existing rolling stock with changes in the traction network parameters by means of thyristor rectifiers installed at traction substations. ...

How to cite: Bannikov E.V., Stepanenko V.P. Prospects of CPT3-I equipment for mine electric locomotives // Journal of Mining Institute. 1979. Vol. 84. p. 78-81.
Article
  • Date submitted
    1978-08-30
  • Date accepted
    1978-10-24
  • Date published
    1979-02-01

Criteria for controlling a mine electric locomotive when the train starts from rest

Article preview

One of the stages of train starting is its setting in motion, defined from the moment the electric locomotive starts moving to the moment the last car starts moving. This stage is characterized by an insignificant transient time (1–5 s) and large dynamic loads arising in the coupling devices of the cars. These loads are 3–10 or more times higher than the hourly value of the electric locomotive tractive force. ...

How to cite: Kordakov V.N. Criteria for controlling a mine electric locomotive when the train starts from rest // Journal of Mining Institute. 1979. Vol. 84. p. 82-84.
Article
  • Date submitted
    1978-08-27
  • Date accepted
    1978-10-01
  • Date published
    1979-02-01

Determination of the degree of compounding of traction motors under starting modes of operation of a mine automated electric locomotive

Article preview

In the use of compound traction motors in mine electric locomotive transport, one of the essential issues is the choice of a compounding system. This issue is especially acute when modernizing existing traction motors intended for automated electric locomotive haulage, when a need arises to automate the starting modes of the electric locomotive. ...

How to cite: Kordakov V.N., Eneev M.U. Determination of the degree of compounding of traction motors under starting modes of operation of a mine automated electric locomotive // Journal of Mining Institute. 1979. Vol. 84. p. 85-87.
Article
  • Date submitted
    1978-08-15
  • Date accepted
    1978-10-24
  • Date published
    1979-02-01

Ways to improve train traffic safety in the automation of electric locomotive haulage

Article preview

One of the directions for improving mine electric locomotive haulage is its automation, which ensures rhythmic train movement, increased operational safety, and higher transport productivity. …

How to cite: Lakota O.B., Kordakov V.N. Ways to improve train traffic safety in the automation of electric locomotive haulage // Journal of Mining Institute. 1979. Vol. 84. p. 88-90.
Article
  • Date submitted
    1978-08-26
  • Date accepted
    1978-10-27
  • Date published
    1979-02-01

Automated mine electric locomotive

Article preview

The development of the mining industry requires solving the issues of mechanization of all production processes, including in mine transport. Currently, electric locomotive transport is used to deliver ore along the main haulage workings. In connection with the growth of ore production volumes and the increasing importance of haulage, the solution of problems of increasing labor productivity and reducing the cost of ore is possible in several directions — increasing weight standards, speeds, automation of transport, etc. ...

How to cite: Aniskin B.G. Automated mine electric locomotive // Journal of Mining Institute. 1979. Vol. 84. p. 91-94.
Article
  • Date submitted
    1978-08-22
  • Date accepted
    1978-10-01
  • Date published
    1979-02-01

Slave vector control of an induction motor by the rotor slip parameter

Article preview

The original control system scheme, intended, according to the authors of this scheme, for controlling the torque of an induction motor, unfortunately, has inaccuracies in the calculations. This led to an unjustified conclusion about the effectiveness of this control system. ...

How to cite: Dartau V.A. Slave vector control of an induction motor by the rotor slip parameter // Journal of Mining Institute. 1979. Vol. 84. p. 95-99.
Article
  • Date submitted
    1978-08-04
  • Date accepted
    1978-10-14
  • Date published
    1979-02-01

Control based on the principle of slave regulation of an electric drive with a double-fed induction machine

Article preview

The use of AC machines in the drive, fed from the stator side and from the rotor side, allows expanding the range of regulation of the rotor speed of the machine. An ordinary induction motor with a wound rotor can serve as the actuator machine. In this case, let us call it a double-fed machine (DFM). ...

How to cite: Dartau V.A. Control based on the principle of slave regulation of an electric drive with a double-fed induction machine // Journal of Mining Institute. 1979. Vol. 84. p. 100-106.
Article
  • Date submitted
    1978-08-12
  • Date accepted
    1978-10-05
  • Date published
    1979-02-01

Induction machine equations for the synthesis of frequency control systems

Article preview

An induction motor with a squirrel-cage rotor is structurally the simplest electrical machine, which has caused a fairly widespread use of this motor in the drive of mining machines. However, the dynamic modes of these machines have not been sufficiently studied. ...

How to cite: Stolyarov I.M., Rosso T.O. Induction machine equations for the synthesis of frequency control systems // Journal of Mining Institute. 1979. Vol. 84. p. 107-112.
Article
  • Date submitted
    1978-08-16
  • Date accepted
    1978-10-15
  • Date published
    1979-02-01

Control units for a thyristor frequency converter in a vector control system

Article preview

The power thyristor inverter control unit ICU must provide control of the frequency and phase of the output voltage of the autonomous inverter of the thyristor frequency converter TFC using two input three-phase voltage systems. For this purpose, at the output of the unit, long thyristor control pulses of the inverter must be formed, necessary for a stable and reliable start-up of the drive. ...

How to cite: Alekseev V.V., Dartau V.A., Pavlov Y.P., Rudakov V.V. Control units for a thyristor frequency converter in a vector control system // Journal of Mining Institute. 1979. Vol. 84. p. 113-119.
Article
  • Date submitted
    1978-08-16
  • Date accepted
    1978-10-29
  • Date published
    1979-02-01

Application of analytical self-tuning loops in electric drives with series correction

Article preview

An ideal automatic control system (ACS) of electric drives would be one that executes commands without errors. It is practically impossible to obtain such a system; one can only strive toward it. …

How to cite: Soloviev A.S., Ambartsumyan N.A. Application of analytical self-tuning loops in electric drives with series correction // Journal of Mining Institute. 1979. Vol. 84. p. 120-123.