About compensation of reactive power in the schemes of power supply of oil and gas producing enterprise
Authors:
About authors
- Perm State Technical University
Abstract
This paper continues research into the state of reactive power compensation at oil-production enterprises. Operation mode of a pump jack is analyzed in order to assess changes in active and reactive power per cycle. A typical work cycle scheme of balanced pump jack was modeled. A curve of active and reactive power changes per working cycle was build for the corresponding pump jack with application of the graphical analytic method.
Область исследования:
(Archived) Geotechnical engineering, powerengineering and automation
Funding:
None
Similar articles
Application of asynchronous motors with double supply and vector regulation as generators for wind power stations
2009 I. Imenokhoev
Automatic system of stabilization of sulphur production from waste gases of autogenous generators