Computer modeling of thermal operation of water cooling unit of magnesium electrolyzer anodes

Authors:
E. A. Alsufev
About authors
  • G.V. Plekhanov Saint Petersburg Mining Institute
Date submitted:
2005-07-19
Date accepted:
2005-08-07
Date published:
2006-04-07

Abstract

The paper presents the results of computer thermal calculation of a water-cooled unit for anode cooling in bubble-free magnesium electrolyzers. Matlab program was used for numerical calculations. The program includes the PDE toolbox for numerical simulation of non-stationary physical fields described by partial differential equations.