Submit an Article
Become a reviewer
Vol 77
Pages:
93-95
Download volume:
RUS
Article

Using the principles of high-frequency humidity control for determining the end of drying of complex bioproducts in vacuum drums

Authors:
A. V. Gvozdev
N. S. Sabadash
Date submitted:
1977-10-18
Date accepted:
1977-12-03
Date published:
1978-04-01

Abstract

The solution of the problem of automatic, control of the end of drying of raw materials in vacuum-horizontal boilers will allow to increase the output of high quality products with lower energy costs, to keep the current standards for shipped products and to obtain a significant economic effect ...

Область исследования:
(Archived) Without section
Go to volume 77

References

  1. Berliner M.A. Control and measurement of humidity. M., Energia, 1973.
  2. Krichevskiy E.S. High-frequency control of moisture content in mineral processing. M., Nedra, 1972.
  3. Liberman S.G., Petrovskiy V.P. Reference book on the production of technical products at meat processing plants. M., Food Industry, 1969. PH 3.

Similar articles

Development of automatic control system of thickening process
1978 V. P. Nazarov
About one variation of the thermophysical method of measuring the moisture content of bulk enrichment products
1978 E. S. Krichevsky, V. P. Terekhov, S. S. Galushkin
Frequency mixers for high-frequency capacitance meters made on the scheme of F-meter
1978 E. A. Kalm
Influence of the schemes of the executive body drive of the mechanohydraulic harvester on its theoretical productivity
1978 B. S. Makhovikov
Capacitive-thermal moisture meter of bulk enrichment products
1978 E. S. Krichevsky, V. P. Terekhov
Using the predictive signal for solving the problem of optimal control of the drying drum
1978 V. G. Deitch, V. V. Stalsky