Submit an Article
Become a reviewer
N. S. Sabadash
N. S. Sabadash

Co-authors

Articles

Article
  • Date submitted
    1977-10-24
  • Date accepted
    1977-12-09

Physical principles of the construction of primary transducers for monitoring droplets in an air or gas flow

Article preview

When operating technological systems associated with the use of an air or gas flow (for example, systems for the purification of industrial gases, pneumatic transport of bulk materials, artificial reduction of air humidity), there is a possibility of liquid droplets entering the air duct. This phenomenon significantly impairs the operating efficiency of the systems under consideration and leads to premature wear of the equipment used. To avoid an emergency situation, such systems are usually provided with a gas-liquid mixture separation unit. The element of such a device that records the moment of liquid carryover is a primary transducer.

How to cite: Krichevsky E.S., Sabadash N.S., Tyushina I.A. Physical principles of the construction of primary transducers for monitoring droplets in an air or gas flow // Journal of Mining Institute. 1978. Vol. 77. p. 76-80.
Article
  • Date submitted
    1977-10-18
  • Date accepted
    1977-12-03

Use of the principles of high-frequency moisture control to determine the end point of drying of complex bioproducts in vacuum drums

Article preview

Solving the problem of automatic control of the end point of drying of raw materials in horizontal vacuum kettles will make it possible to increase the output of high-quality products with lower energy consumption, comply with the current standards for shipped products, and achieve a significant economic effect. ...

How to cite: Gvozdev A.V., Sabadash N.S. Use of the principles of high-frequency moisture control to determine the end point of drying of complex bioproducts in vacuum drums // Journal of Mining Institute. 1978. Vol. 77. p. 93-95.
Article
  • Date submitted
    1971-07-26
  • Date accepted
    1971-09-14

Varicapsfor increasing the sensitivity of capacitive moisture meters

Article preview

Numerous methods of measuring the moisture content of solid, liquid and bulk materials are known: conductometric, based on the use of the relationship between moisture and the active resistance of the material; capacitive – between moisture and dielectric permittivity (more precisely – apparent capacitance); neutron; nuclear magnetic resonance – NMR, etc.

How to cite: Krichevsky E.S., Avdeeva A.F., Sabadash N.S., Kalm E.A. Varicapsfor increasing the sensitivity of capacitive moisture meters // Journal of Mining Institute. 1972. Vol. 62. Iss. 1. p. 27-30.