One of the quality indicators of the produced mining and chemical raw materials and processed products is their moisture content. Reliable control of humidity requires a lot of labor and time.
At the Apatit production association, apatite ore is delivered from the mines to the concentrators by railroad dumpcars with a capacity of 100 tons. Loading of the dumpcars is carried out by a hatchman from the ore chutes or the bunkers of loading stations. This article considers a system for the automatic counting of only fully loaded dumpcars, which can be used in an automated load-control system.
For controlling the composition of substances, their molecular state, and moisture content of various materials, the dependence of the dielectric permittivity value on these parameters is widely used in measurement technology. In this case the change of dielectric permittivity of the substance filling the measuring capacitor, which is the primary measuring transducer, leads to a change in its initial electrical capacitance. Continuous capacitance measurement makes it possible to plot a graph reflecting the nature of the variation of the controlled parameter over time. ...
In discrete rapid monitoring of the moisture content of dispersed materials, devices based on the E12-1A instrument, whose simplified circuit is shown in Figure 1, are in some cases used. The range and accuracy of moisture measurements of materials are determined not only by the design of the sensor, but also by the circuit of the measuring oscillator. The range of moisture measurement can also be extended and the effect of losses reduced by increasing the overall gain of the stage, for example, by replacing the cathode follower with an aperiodic amplifier with an anode load.
Numerous methods of measuring the moisture content of solid, liquid and bulk materials are known: conductometric, based on the use of the relationship between moisture and the active resistance of the material; capacitive – between moisture and dielectric permittivity (more precisely – apparent capacitance); neutron; nuclear magnetic resonance – NMR, etc.
At present, either electrical resistance (conductivity) or capacitance value is used as an output parameter of electrode sensors used in mineral processing. On the basis of theoretical studies by E. S. Krichevsky and A. I. Nudelman (Leningrad Mining Institute) it is possible to create special circuits that allow transforming the value of resistance or capacitance in electrode sensing devices into the phase angle between the current in the measuring circuit and the voltage supplying this device.