Sensitivity of the capacitive primary transducer for density
Authors:
Abstract
Let us consider the principle underlying the measurement of pulp density by the capacitive method in the case of a non-contact two-electrode measuring cell. In the analysis we will use the equation for the imaginary Bp component of the conductivity of the equivalent circuit of the cell. ...
Область исследования:
(Archived) Without section
Funding:
None
References
- Zhilkina E.V. Analysis of phosphorite concentrate slurry density by capacitive method. - Zapiski Gornogo Instituta, 1975, vol. 68, issue 1. (in Russian)
- Zhilkina E.V., Lakhter B.S. Research of capacitive and conductometric methods of pulp density measurement. -Izv. vuzov. Gornyi Zhurnal, 1976, no. 11. (in Russian)
- Zarinsky V.A., Ermakov V.I. High-frequency chemical analysis. M., Nauka, 1970. (in Russian)
- Lopatin B.A. Conductometry. Novosibirsk, Izd. Sib. otd. AN SSSR, 1964. (in Russian)