Submit an Article
Become a reviewer
Vol 77
Pages:
113-116
Download volume:
RUS
Article

Investigation of the design parameters of the conductometric slurry density transducer

Authors:
E. V. Zhilkina
Date submitted:
1977-10-11
Date accepted:
1977-12-07
Date published:
1978-04-01

Abstract

The objective of the study was to investigate the potential electric fields of a seven-electrode conductometric transducer in order to find its optimal design parameters. Since the seven-electrode converter is two four-electrode cells connected in series, modeling was performed for the case of a four-electrode primary converter .....

Область исследования:
(Archived) Without section
Funding:

None

Go to volume 77

Similar articles

Using the principles of high-frequency humidity control for determining the end of drying of complex bioproducts in vacuum drums
1978 A. V. Gvozdev, N. S. Sabadash
Frequency mixers for high-frequency capacitance meters made on the scheme of F-meter
1978 E. A. Kalm
Pneumatic control system of the dust suppressing curtain
1978 E. K. Kersky
Method of measuring cargo weight in dump truck by built-in weighing device
1978 M. A. Semenov
Pneumohydraulic suspension of heavy-duty dump trucks as a source of measuring information for built-in weighing devices
1978 V. A. Gardzish, M. A. Semenov
Resolution ability of automated thermovacuum moisture meters
1978 A. G. Volchenko