Submit an Article
Become a reviewer
Vol 77
Pages:
72-75
Download volume:
RUS
Article

Correction of nonlinearity of temperature dependence of thermistor resistance in the bridge circuit

Authors:
A. A. Seliverstov
Date submitted:
1977-10-09
Date accepted:
1977-12-10
Date published:
1978-04-01

Abstract

Due to a number of advantages over other types of temperature transducers thermistors are widely used in various devices of thermal control - moisture meters, flow meters, level gauges, etc. In these devices, in order to exclude the influence of the initial tc temperature of the material, a differential inclusion of two thermistors having identical temperature dependences is usually used in the area of possible change of the initial temperature of the material ...

Область исследования:
(Archived) Without section
Go to volume 77

References

  1. Kaganov M.A. Calculation of electric circuits with thermistors for modeling of linear temperature dependence. - Collected works on agronomic physics. L., Gidrometeoizdat, 1972, issue 33.
  2. Kaganov M.A., Vinarov A.Z. Questions of methodology of calculation of schemes of temperature measurement with posistors. - Collected Works on Agronomic Physics. L., AFI, 1976, vol. 41.
  3. Krichevskiy E.S., Seliverstov A.A. Heat-pulse moisture meters. Measurement Technique, 1978, № 7.

Similar articles

Capacitive-thermal moisture meter of bulk enrichment products
1978 E. S. Krichevsky, V. P. Terekhov
Optimal load distribution during concentrate drying at concentrators
1978 V. G. Deitch, V. V. Stalsky, S. V. Storozhenko
Primary converters of thermovacuum moisture meters
1978 A. G. Volchenko, R. M. Proskuryakov
High-frequency system of express control of moisture content of KSMC concentrates
1978 A. F. Avdeeva, A. V. Shipulin
Features of measuring circuits with parametric modulation
1978 V. G. Valeev, A. F. Avdeeva
Method of measuring the resistance of the filtering layer of a vacuum filter when studying it as an object of automatic control
1978 A. G. Tsai