Capacitive-thermal moisture meter of bulk enrichment products
Abstract
High-frequency moisture meters have been successfully used to measure the moisture content of a number of beneficiation products. However, when measuring the moisture content of bulk materials having low goodness-of-fit (e.g., metal-containing cakes), there are difficulties in developing circuits that allow measurement of the electrical capacitance of the material under low goodness-of-fit conditions ...
Область исследования:
(Archived) Without section
References
- Berliner M.A., Vasilieva I.I. Determination of moisture content of materials by cooling curves. Zavodskaya laboratoriya, 1969, № 1, pp. 64-65.
- Sensor for moisture measurement / E.S. Krichevskiy, S.S. Galushkin, V.P. Terekhov, A.V. Mayorov. A.p. № 516952 (USSR). B.I. 1976, № 21.
- Krichevskiy E.S. High-frequency control of moisture content in mineral processing. M., Nedra, 1972, p. 154.
- Krichevskiy E.S., Galushkin S.S., Terekhov V.P. Experience of operation of systems of continuous control of moisture content of apatite concentrate. Chemical Industry, 1975, № 2, pp. 59-62.
- Krichevskiy E.S., Galushkin S.S., Terekhov V.P. Device for discrete moisture measurements. A.c. № 521509 (USSR). B.I. 1976, № 26.
- Chudnovskiy A.F. Thermophysical method for determination of moisture content of capillary porous materials. Journal of Technical Physics 1954, vol. 12. pp. 2190-2201.
Similar articles
Digital adder of cargo weight for built-in weighing devices
1978 Yu. A. Alekseenko, V. A. Gardzish, M. A. Semenov
Optimal load distribution during concentrate drying at concentrators
1978 V. G. Deitch, V. V. Stalsky, S. V. Storozhenko
Boundaries of applicability of the search-free method of optimization of beneficiation processes
1978 V. I. Zlatkin