Submit an Article
Become a reviewer

Search articles for by keywords:
устройства транспортирования

Metallurgy and concentration
  • Date submitted
    2022-05-17
  • Date accepted
    2022-09-06
  • Date published
    2022-11-03

On the need to classify rock mass fed to dry magnetic separation

Article preview

The hypothesis of a possible use of dry magnetic separation is substantiated on the example of ores from ferruginous quartzite deposits operated by plants of PAO “Severstal” Holding. Size class of ore after medium crushing is –80+0 mm when the vibrating feeder is used for feeding ore mass to the separation zone. The rationale is based on the analysis of video recording of physical simulation on a laboratory drum magnetic separator of SMBS-L series, in the VSDC Video Editor, and simulation modelling of dry magnetic separation on its virtual prototype in Rocky DEM software package. It has been proved that the use of a vibrating feeder for feeding the material to the working area of a magnetic separator makes it possible to: form a monolayer on the surface of the vibrating feeder chute with a thickness close to the maximum size of a lump of separated ore; implement batch feed of material to the separation zone; increase the spacing between lumps in the separation zone when passing through the free fall area, thereby allowing dry magnetic separation of ferruginous quartzites of size class –80+0 mm without pre-preparation.

How to cite: Shibaeva D.N., Tereshchenko S.V., Asanovich D.A., Shumilov P.A. On the need to classify rock mass fed to dry magnetic separation // Journal of Mining Institute. 2022. Vol. 256 . p. 603-612. DOI: 10.31897/PMI.2022.79
Electromechanics and mechanical engineering
  • Date submitted
    2021-01-20
  • Date accepted
    2021-03-15
  • Date published
    2021-04-26

Improving the quality of electricity in the power supply systems of the mineral resource complex with hybrid filter-compensating devices

Article preview

The urgency and necessity of choosing and justifying the structures of hybrid filter-compensating devices based on series and parallel active filters to improve the quality of electricity in the power supply systems of enterprises of the mineral resource complex is shown. Mathematical models of hybrid filter compensating devices based on parallel and series active filters have been developed. Based on these mathematical models, computer simulation models of the indicated hybrid structures have been developed. The results of simulation showed the effectiveness of the correction of power quality indicators in terms of reducing the level of higher harmonics of current and voltage, as well as voltage deviations. The degree of influence of filter-compensating devices on the power quality indicators, which determine the continuity and stability of the technological process at the enterprises of the mineral resource complex, have been revealed. It has been established that a hybrid filter-compensating device based on a parallel active filter can reduce the level of higher harmonics of current and voltage by more than 90 and 70 %, respectively, and based on a series active filter, it can reduce the level of higher harmonics of voltage by more than 80 %. Based on the simulation results, the possibility of compensating for the reactive power of a hybrid structure based on parallel active and passive filters has been revealed. The possibility of integrating hybrid filter-compensating devices into more complex multifunctional electrical systems for the automated improvement of the quality of electricity is substantiated, as well as the expediency and prospects of their use in combined power supply systems based on the parallel operation of centralized and autonomous sources of distributed generation.

How to cite: Sychev Y.A., Zimin R.Y. Improving the quality of electricity in the power supply systems of the mineral resource complex with hybrid filter-compensating devices // Journal of Mining Institute. 2021. Vol. 247 . p. 132-140. DOI: 10.31897/PMI.2021.1.14
Electromechanics and mechanical engineering
  • Date submitted
    2016-11-14
  • Date accepted
    2017-01-09
  • Date published
    2017-04-14

Method of restoring strength determination test

Article preview

The main requirements for an electric unit at the stages of its design, development, production and usage are described in technical specifications (TS) and standards (GOST). The electric unit should work in accordance with a specific purpose and have significant reliability, durability and safety. The reliability and durability of electric unit significantly depends on restoring strength speed value, that is growth of breakage voltage in arc pass for eliminating repeated arc strike. This article describes several methods of test identification of restoring strength, which were carried out at special testing laboratory units. They are described in relation to conditions of measuring the residual arc column of AC current after it reaches zero point and can be used in designing arc blowout units of low voltage.

How to cite: Apollonskii S.M., Kuklev Y.V. Method of restoring strength determination test // Journal of Mining Institute. 2017. Vol. 224 . p. 235-239. DOI: 10.18454/PMI.2017.2.235
Mining machine, electrical engineering and electromechanics
  • Date submitted
    2010-07-01
  • Date accepted
    2010-09-23
  • Date published
    2011-03-21

Improving the efficiency of system of deleting waste on Udachny GOK

Article preview

Examined ways to improve the efficiency of hydrotransport systems. A method for determining the most advantageous modes of GTP. The calculation of basic characteristics of the flow of pulp when the grain size, density and quantity released to the enrichment of solid material to installation hydrotransport concentrator.

How to cite: Dokukin V.P., Velnikovskiy A.A. Improving the efficiency of system of deleting waste on Udachny GOK // Journal of Mining Institute. 2011. Vol. 189 . p. 83-86.