Specific features of hydrotransport systems operation in winter conditions
Authors:
About authors
- G.V. Plekhanov Saint Petersburg Mining University
Abstract
The analysis of operating conditions of above-ground slurry pipelines of mining enterprises in conditions of negative temperatures is carried out. The results of theoretical and experimental studies of the heat exchange process in the two-phase flow taking into account the distribution of velocity and concentration of the solid phase across the cross section of the pipe are presented.
Область исследования:
(Archived) Technological machinery and equipment of mining and oil & gas industries
Similar articles
Technologies and equipment for peat extraction and processing
2004 V. G. Selennov, E. A. Shchipitin, A. V. Mikhailov
Design and simulation of a vector-controlled electric drive for a drilling rig rotator
2004 V. V. Alekseev