The values of dynamic viscosity of copper-nickel sulfate solution with boundary parameters Cu2+-50-60 g/dm3, Ni2+-20-25 g/dm3, H2SO4-140-180 g/dm3 in the temperature range of 50-70° have been determined. A simplified equation for analyzing the viscosity of the solution depending on its composition and temperature is proposed. Technological graphs of solution viscosity simplifying its determination are given.