Submit an Article
Become a reviewer
Vol 178
Pages:
130-134
Download volume:
RUS
Article

Dielcometric meter of humidity of bulk media

Authors:
S. S. Galushkin
About authors
  • G.V. Plekhanov Saint Petersburg Mining Institute
Date submitted:
2007-11-23
Date accepted:
2008-01-08
Date published:
2008-11-18

Abstract

A method is offered and the device bringing into effect this method which excludes the impact of electrode wear and inter-electrode space on metrological parameters of moisture indicators is presented. It is shown that by use of the known capacitance sensors with the help of the proposed algorithm of transformation it is possible to switch from the capacitance meters of dispersion material composition to pure dielcometric meters. In this situation metrological parameters do not depend on part specifications of their sensors. In addition the impact of all non-diagnostic markers is excluded in this device.

Область исследования:
(Archived) Electric drive, power supply, automation and control of mining and oil and gas production
Go to volume 178

Similar articles

Automatic sectionalization in electrical networks with voltage 6-10 kV
2008 Yu. L. Zhukovskiy, E. Kh. Muratbakeev
Calculation of parameters of pipe-water transportation of hydraulic mixtures with high concentrations of solid phase
2008 V. I. Aleksandrov, V. P. Pirozhenko, P. B. Gurkin
Analysis of calculation methods of technogenic risk at operation of main gas pipelines
2008 I. Yu. Podavalov
Dynamic and energy indices of control systems of asynchronous drive of mining equipment
2008 V. V. Alekseev, V. N. Yazev
Relevance of application of centralized protection with inverse dependent time-current characteristic of RXIDG type for networks with resistive neutral groundi
2008 M. A. Bychin
Long-range redundancy of protection failures in 0,4 kV networks at gas transportation enterprises
2008 A. V. Belenko, S. P. Petrov