Diagnostic method for measurements of emission parameters of thermoemission cathodes
Authors:
About authors
- Ph.D., Dr.Sci. professor Saint Petersburg State Mining Institute (Technical University)
Abstract
This article deals with the diagnostic method of emission parameters of thermo emission cathodes by the transverse magnetic field. The knudsen Cs-Ba-diode with the surface ionization are investigated.
Область исследования:
(Archived) Applied and fundamental research in physics and mathematics
Keywords:
surface ionization
work function of cathodes
coefficients of reflection of heat electrons
Knudsen plasma
thermo electronic emission
References
- Mustafaev A.S.. Diagnostics methods of anisotropic plasmas in thermionic plasma energetics: Refer… Doctor of Phys.-math. Sci. ONTI FEI. Obninsk, 2003.
- Mustafaev A.S. Integral methods resolving of kinetic equations / Mustafaev A.S., Babanin V.I., Ender A.Ya.; FTI AN USSR. Leningrad, 1971.
- Mustafaev A.S. Influence of transverse magnetic fields in undercompensation regime of TEC / Mustafaev A.S., Babanin V.I., Ender A.Ya.; FTI AN USSR. Leningrad, 1971