Efficiency increasing of condenser batteries operation in mining enterprise`s electric circuits
Authors:
About authors
- post-graduate student Saint Petersburg State Mining Institute (Technical University)
Abstract
This work contains the method of effective reactive power compensation at the expense of high harmonics reduction. The decrease of condenser batteries overloading from the high harmonics is based on variation of condenser power depending on current and voltage spectral structure, electric network parameters and load power.
Область исследования:
(Archived) Mining machine, electrical engineering and electromechanics
Keywords:
high harmonics
overloading
condenser batteries
reactive power
compensation
electric network
load
power quality