The paper presents a number of experimental techniques for detecting in amorphous tantalum oxide films structural defects, which accelerate film destruction processes in a strong electric field and thus are potentially dangerous under prolonged thermoelectric stresses applied to capacitor structures. It is shown that the anomalous frequency dependence of dielectric losses and increase of the leakage current over time can identify potentially unreliable capacitors.