Electrical methods for nondestructive quality control of capacitors metal-oxide structures
About authors
- 1 — Saint Petersburg State Mining Institute (Technical University)
- 2 — Herzen Russian State pedagogical university
Abstract
The paper presents a number of experimental techniques for detecting in amorphous tantalum oxide films structural defects, which accelerate film destruction processes in a strong electric field and thus are potentially dangerous under prolonged thermoelectric stresses applied to capacitor structures. It is shown that the anomalous frequency dependence of dielectric losses and increase of the leakage current over time can identify potentially unreliable capacitors.
Область исследования:
(Archived) Basic research in natural sciences
Funding:
None
Similar articles
Swinging movement autoresonant electric drive with nonsymmetric excitation of dynamically counter-balanced drilling string on carrying cable
2011 E. A. Zagrivnyi, A. N. Fomenko
Some features of working out of imitating economic- mathematical models for open –cast mine
2011 L. I. Boguslavskaya
Stress-strain condition of the ore massive within the second working modeling
2011 A. G. Protosenya, K. G. Sinyakin
Substantiation of pumped volumes of flow angularity compositions in injection wells
2011 A. R. Mavliev, M. K. Rogachev, D. V. Mardashov