Electrical methods for nondestructive quality control of capacitors metal-oxide structures
About authors
- 1 — Saint Petersburg State Mining Institute (Technical University)
- 2 — Herzen Russian State pedagogical university
Abstract
The paper presents a number of experimental techniques for detecting in amorphous tantalum oxide films structural defects, which accelerate film destruction processes in a strong electric field and thus are potentially dangerous under prolonged thermoelectric stresses applied to capacitor structures. It is shown that the anomalous frequency dependence of dielectric losses and increase of the leakage current over time can identify potentially unreliable capacitors.
Область исследования:
(Archived) Basic research in natural sciences
Funding:
None
Similar articles
Experimental and theoretical studies and justification of geotechnology of stock pile formation from pelletized gold-bearing ores in order to enhance its filtration properties
2011 S. B. Tataurov
Geomechanical substantiation of optimal parameters of pillars in multientey scheme of coal seams development
2011 S. G. Kokoev
The autoresonant asynchronous electric drive of dynamically counterbalanced drilling string on carrying cable with swinging movement fluctuations amplitude stabilization
2011 E. A. Zagrivnyi, V. V. Ivanik