Abstract
The paper presents a number of experimental techniques for detecting in amorphous tantalum oxide films structural defects, which accelerate film destruction processes in a strong electric field and thus are potentially dangerous under prolonged thermoelectric stresses applied to capacitor structures. It is shown that the anomalous frequency dependence of dielectric losses and increase of the leakage current over time can identify potentially unreliable capacitors.
Область исследования:
(Archived) Basic research in natural sciences
Funding:
None
Similar articles
Researches of coagulation of dust fraction at application of the aerofoamy way of dust-depressing
2011 A. A. Kamenskii
Parameters of high viscosity oils transportation in the form of emulsion research in order to its optimization
2011 V. I. Aleksandrov, A. P. Khrabrov
Utilization of enrichment waste of diamondiferous rock accounting peculiarities of M.V.Lomonosov deposit
2011 A. Yu. Oblitsov