Energy performance of asynchronous valve cascade for mine hoist drive

Authors:
E. M. Proskuryakov
Date submitted:
1965-07-24
Date accepted:
1965-09-08
Date published:
1966-11-15

Abstract

The energy indicators - efficiency (efficiency) and power factor (cos φ) - largely determine the choice of a particular variable speed drive system. The efficiency of a cascade can be determined through the power losses in the cascade ...

Область исследования:
(Archived) Without section
Go to volume 53

References

  1. Andreev V. P. Sabinin Y. A. Fundamentals of Electric Drive. Gosenergopzdat, 1963.
  2. Butaev F. I. Ettinger E. L. Valve Electric Drive. Gosenergoizdat, 1951.
  3. Zhivov L. G. Drive and Automation of Lifting Machines. Mashinostroenie, 1964.
  4. Kaganov I. L. Electronic and Ion Converters. P. III. Gosenergoizdat, 1956.
  5. Chizhenko K. M., Vydolob Yu. F. Valve cascade with compensating inverter. Proc. Kiev Polytechnic Institute, vol. XXXIX, 1962.

Similar articles

Calculation of electrified mining machines productivity
1966 Ya. P. Grinberg
To the question of control optimization of hoisting machines
1966 L. Shklyarsky, B. Fijalkovsky
Contactless elements in systems of automated control of mine asynchronous electric drives
1966 Yu. I. Fel
Wide-range generator for research of high-frequency parameters of mine power networks
1966 V. I. Gvozdev, A. S. Soloviev
Influence of the electric drive system on the dredger characteristic
1966 D. G. Povolotsky
Calculation of reliability of electric power distribution systems at open-pit mining operations