Energy performance of asynchronous valve cascade for mine hoist drive
Authors:
Abstract
The energy indicators - efficiency (efficiency) and power factor (cos φ) - largely determine the choice of a particular variable speed drive system. The efficiency of a cascade can be determined through the power losses in the cascade ...
Область исследования:
(Archived) Without section
References
- Andreev V. P. Sabinin Y. A. Fundamentals of Electric Drive. Gosenergopzdat, 1963.
- Butaev F. I. Ettinger E. L. Valve Electric Drive. Gosenergoizdat, 1951.
- Zhivov L. G. Drive and Automation of Lifting Machines. Mashinostroenie, 1964.
- Kaganov I. L. Electronic and Ion Converters. P. III. Gosenergoizdat, 1956.
- Chizhenko K. M., Vydolob Yu. F. Valve cascade with compensating inverter. Proc. Kiev Polytechnic Institute, vol. XXXIX, 1962.
Similar articles
Regularities of load distribution of quarry traction substations and traction network sections
1966 V. A. Aleksandrov
The nature of change and current efficiency factor of open pit electric locomotives
1966 V. A. Alexandrov