Measurement of hydro-mixture density by radioisotope density meter PZHR-2M

Authors:
V. N. Pokrovskaya
Yu. P. Boytsov
D. G. Povolotsky
Date submitted:
1966-07-24
Date accepted:
1966-09-06
Date published:
1967-09-21

Abstract

During the research of the hydrofilling complex operation mode, a radioisotope density meter PZHR-2M with the measuring range of 0.5 g/cm3 was used to measure the density of the hydraulic mixture. This range in some cases did not meet the conditions of the hydrofill complex operation. Often the mixing device could not provide complete filling of the pipeline. Then air moved along the pipeline with the pulp, and the device showed the density value less than one. For correct evaluation of the work of the stowing complex it was necessary to know the character of pulp movement with incomplete utilization of its cross-section. For this purpose the measuring limits of the instrument were extended by means of lead tared plates placed between the source unit and the pipeline. By changing the thickness and number of plates, it was possible to have several measurement ranges: 0-0.5; 0.5-1.0; 1.0-1.5 g/cm3 ...

Область исследования:
(Archived) Information on scientific works of the Leningrad Mining Institute
Funding:

None

Go to volume 54

Similar articles

Ways to increase the utilization of locomotive-car fleet of Apatit Combine
1967 L. G. Tymovsky, G. V. Dubovitsky
Application of the rope traction organ in conveyors
1967 A. M. Factorovich, O. D. Serebrennikov
Prof. V.I. Gerontiev (1889-1966)
1967 Kollektiv kafedry Staff of the Department of Mining Mechan
To the selection of parameters of elastic guide vessels of vertical mine lifts
1967 E. Ya. Belostotsky
Influence of drill bit design on drilling cost (with SVB-2 machines at Estonslanets field).
1967 A. I. Talko, R. M. Petrov, E. A. Vaher
Investigation of the process of rock destruction by fine-diamond crowns
1967 S. N. Tarakanov