This article describes operations from the well construction cycle where the cement rock behind the casing is subjected to dynamic action (impacts of the drill stem during drilling and normalization of the cement sleeve, secondary drilling operations, hydraulic fracturing, etc.). The developed cement mortar compositions were tested following API 10B-2, API 10B-6, API STD-65-2, and GOST 28985-91 standards. The composition of the cement system without the use of imported components (CM-5) was developed, which improved elastic and strength properties compared to existing industry solutions. An improvement in the elastic and strength features and technological properties of cement rock when using epoxy resins was identified, the optimal composition of the cement-and-epoxy grout was determined, and the internal structure of the formed backfill rock, its permeability, and porosity were studied.