B. I. Komarov
B. I. Komarov

Co-authors

Articles

Article
  • Date submitted
    1975-07-14
  • Date accepted
    1975-09-23

Asynchronous motor with series capacitors under periodic loading

Article preview

The loads of mining machine drives are characterised by significant irregularity and, as correlation analysis of the operating modes of extraction and tunnelling combines demonstrates, contain periodic components with a frequency range of 0.5–20 Hz. In extensive mine networks, cutter-loader electric motors often cannot stably sustain a load equal to their rated power. ...

How to cite: Ivanov O.V., Komarov B.I., Sigarreta A.D. Asynchronous motor with series capacitors under periodic loading // Journal of Mining Institute. 1976. Vol. 70. Iss. 1. p. 38-42.
Article
  • Date submitted
    1975-07-15
  • Date accepted
    1975-09-03

Study of capacitor braking of squirrel-cage induction motors using an analogue computer

Article preview

In electric drive systems, capacitive braking of squirrel-cage induction motors is employed either autonomously or in combination with other operating modes. The braking torque on the motor shaft, depending on the circuit configuration and initial conditions, arises either from machine self-excitation, capacitor discharge, or a combination of both effects simultaneously. ...

How to cite: Ivanov O.V., Komarov B.I. Study of capacitor braking of squirrel-cage induction motors using an analogue computer // Journal of Mining Institute. 1976. Vol. 70. Iss. 1. p. 43-47.
Article
  • Date submitted
    1965-07-14
  • Date accepted
    1965-09-17

Mechanical properties of asynchronous motors in mine networks with series capacitors

Article preview

Voltage losses due to the large length of mine distribution networks, prevent the normal operation of electric drives of mining machines and mechanisms. One of the effective means of compensation of voltage losses, and hence a means of ensuring normal operation of electric motors in such networks, is longitudinal capacitive compensation. Its application, however, is complicated by self-excitation of induction motors. The effect of self-excitation can be so significant that normal operation of electric motors, despite compensation of voltage losses, will be impossible ....

How to cite: Bauman V.G., Ivanov O.V., Kwiatkowski V.M., Komarov B.I. Mechanical properties of asynchronous motors in mine networks with series capacitors // Journal of Mining Institute. 1966. Vol. 53. Iss. 1. p. 28-34.
Article
  • Date submitted
    1965-07-20
  • Date accepted
    1965-09-19

Investigation of Transients in Nonlinear Electric Circuit on Mathematical Analog Machine MN-7

Article preview

When an unloaded transformer is switched on through the capacitors of the CPC longitudinal compensation unit, undamped resonant oscillations can occur in the circuit. The frequency of these oscillations is usually 1/3 of the mains frequency (in case of subharmonic resonance) or equal to the mains frequency (in case of ferroresonance of voltages). Resonant oscillations are known to be accompanied by a sharp increase in transformer magnetizing current and overvoltages both on the CPC itself and on the transformer ...

How to cite: Bauman V.G., Ivanov O.V., Kwiatkowski V.M., Komarov B.I., Proskuryakov E.M. Investigation of Transients in Nonlinear Electric Circuit on Mathematical Analog Machine MN-7 // Journal of Mining Institute. 1966. Vol. 53. Iss. 1. p. 85-90.
Article
  • Date submitted
    1965-07-27
  • Date accepted
    1965-09-28

Investigation of the process of transformers switching on through the longitudinal compensation unit

Article preview

The installation of longitudinal compensation (LCC) of voltage losses in the distribution network of the mining site was first tested in production conditions at one of the sites of the Kirov mine of the Slantsy Combine in 1964. In the experimental operation of the CPC proved the feasibility and efficiency of automatic voltage regulation by series capacitors in the network of the site. Inclusion of the longitudinal compensation unit allows to get voltage increase at the longwall face distribution point by 20-25% at engine starts and by 10-15% at nominal load ...

How to cite: Bauman V.G., Kwiatkowski V.M., Ivanov O.V., Komarov B.I., Proskuryakov E.M. Investigation of the process of transformers switching on through the longitudinal compensation unit // Journal of Mining Institute. 1966. Vol. 53. Iss. 1. p. 91-95.
Article
  • Date submitted
    1960-07-09
  • Date accepted
    1960-09-24

Voltage regulation by series capacitors and self-excitation of induction motors in mine networks

Article preview

Issues of automatic voltage regulation in local electrical networks are an important part of the overall problem of complex mechanization and automation of production processes in the mining industry. Stable voltage level is necessary for stable operation of automatic devices, more complete utilization of natural mechanical properties of electric drives, reduction/loss of electric energy in local distribution networks.

How to cite: Rysev A.V., Ivanov O.I., Komarov B.I., Bauman V.G. Voltage regulation by series capacitors and self-excitation of induction motors in mine networks // Journal of Mining Institute. 1961. Vol. 45. Iss. 1. p. 74-83.