Asynchronous motor with series capacitors under periodic loading
Abstract
The loads of mining machine drives are characterised by significant irregularity and, as correlation analysis of the operating modes of extraction and tunnelling combines demonstrates, contain periodic components with a frequency range of 0.5–20 Hz. In extensive mine networks, cutter-loader electric motors often cannot stably sustain a load equal to their rated power. ...
Область исследования:
(Archived) Without section
Funding:
None
References
- х Glushko V.V. Operating mode characteristics of mining machines and their automatic control. M., Nedra, 1973.
- хх Ivanov O.V., Kvyatkovsky V.M., Komarov B.I. Study of self-oscillation in induction motors within networks featuring series capacitors. - Electricity, 1969, No. 3.
Similar articles
Control of direct frequency conversions from AC signals in block vector regulation systems for induction drives
1976 V. A. Dartau, Yu. P. Pavlov, E. M. Smirnov, V. N. Yazev
Rotation drive system for ball mills using the DFC-SM (Direct Frequency Converter - Synchronous Motor) configuration
1976 I. M. Stolyarov, Z. B. Sleptsova
Adjustable main drive system for coal shearers using the DFC-IM (Direct Frequency Converter - Induction Motor) configuration
1976 Yu. P. Pavlov, V. V. Rudakov, V. S. Solovev, Ya. P. Grinberg