Automatic bulk solids moisture in stream control system

Article preview

Automatic moisture in fine-dyspersated stream control system based on microwave frequency method is presented. Minimizing means of interrupting factors peculiar to this method of measurement are produced and systematically proved.

How to cite: Galushkin S.S., Vishniak B.A., Smirnov V.N. Automatic bulk solids moisture in stream control system // Journal of Mining Institute. 2010. Vol. 187. p. 40-42.
Article
  • Date submitted
    2009-09-19
  • Date accepted
    2009-11-15

Potassium chloride content in ore and products оf recycling automatic control system

Article preview

Potassium chloride percentage in continuous transported ore flows and products of potassium plants recycling automatic control system is offered and described. It differs fundamentally from used before ones at bulk solids containing natural radio-activity elements effective constituents producing and recycling plants. Sensing device is used in this information-measuring system (IMS). It allows to realize automatic control in flows for that instantaneous productivity fluidity in wide limits is resided. Using such IMS gives considerable economic effect by measurements error lowering and their quickness increase.

How to cite: Galushkin S.S., Vishnyak B.A., Smirnov V.N. Potassium chloride content in ore and products оf recycling automatic control system // Journal of Mining Institute. 2010. Vol. 187. p. 43-46.
Article
  • Date submitted
    2007-11-23
  • Date accepted
    2008-01-08

Dielcometric meter of humidity of bulk media

Article preview

A method is offered and the device bringing into effect this method which excludes the impact of electrode wear and inter-electrode space on metrological parameters of moisture indicators is presented. It is shown that by use of the known capacitance sensors with the help of the proposed algorithm of transformation it is possible to switch from the capacitance meters of dispersion material composition to pure dielcometric meters. In this situation metrological parameters do not depend on part specifications of their sensors. In addition the impact of all non-diagnostic markers is excluded in this device.

How to cite: Galushkin S.S. Dielcometric meter of humidity of bulk media // Journal of Mining Institute. 2008. Vol. 178. p. 130-134.
Article
  • Date submitted
    1984-10-30
  • Date accepted
    1984-12-21

Method of stabilization of active losses in sensors of autogenerator high-frequency moisture meters

Article preview

In high-frequency moisture meters with capacitive sensor it is necessary to minimize the influence of variable active losses of the controlled material on the measurement results.

How to cite: Galushkin S.S., Sokolov A.A. Method of stabilization of active losses in sensors of autogenerator high-frequency moisture meters // Journal of Mining Institute. 1985. Vol. 106. p. 63-67.
Article
  • Date submitted
    1977-10-29
  • Date accepted
    1977-12-02

About one variation of the thermophysical method of measuring the moisture content of bulk enrichment products

Article preview

The electrophysical characteristics of beneficiation products arriving at mining and processing plants from different deposits tend to be heterogeneous ...

How to cite: Krichevsky E.S., Terekhov V.P., Galushkin S.S. About one variation of the thermophysical method of measuring the moisture content of bulk enrichment products // Journal of Mining Institute. 1978. Vol. 77. p. 40-44.
Article
  • Date submitted
    1974-07-09
  • Date accepted
    1974-09-10

On the choice of construction materials for sensors of continuous high-frequency moisture control

Article preview

In the course of long-term operation of continuous moisture-metric systems developed at the Department of Automation of Production Processes of the Leningrad Mining Institute, a significant influence on their operation of the wear of the base and working electrodes of the sensor. ...

How to cite: Terekhov V.P., Galushkin S.S. On the choice of construction materials for sensors of continuous high-frequency moisture control // Journal of Mining Institute. 1975. Vol. 68. Iss. 1. p. 23-24.
Article
  • Date submitted
    1974-07-02
  • Date accepted
    1974-09-10

Application of thermoresistance in the compensation circuit of F-meter type moisture meter

Article preview

In a discrete moisture-metric system of F-meter type the whole set of measurements by the capacitive component is brought to the graduation temperature in accordance with the temperature coefficient of the capacitance of the measured material...

How to cite: Krichevsky E.S., Terekhov V.P., Galushkin S.S. Application of thermoresistance in the compensation circuit of F-meter type moisture meter // Journal of Mining Institute. 1975. Vol. 68. Iss. 1. p. 54-57.
Article
  • Date submitted
    1971-07-15
  • Date accepted
    1971-09-02

About one disturbance in systems of continuous control of bulk materials moisture content

Article preview

In the development of high-frequency continuous humidity control systems, efficient and reliable sensors are the most labor-intensive. Moisture sensors are usually in contact with bulk material or are in close proximity to it, exposed to vibrations, temperature effects, abrasion, environmental effects (dampness, dustiness, chemical activity), i.e. interfering factors that distort the information.

How to cite: Krichevsky E.S., Galushkin S.S. About one disturbance in systems of continuous control of bulk materials moisture content // Journal of Mining Institute. 1972. Vol. 62. Iss. 1. p. 8-17.