Abstract

The possibilities of controlling the temperature of the caisson belt of Vanyukov furnace are studied. The process of heat transfer through the multilayer furnace wall and the process of heat transfer from the caisson to the cooling water are considered. Based on the results of calculations and literature data, the relationship between the temperature of the caissoned furnace belt and changes in the temperature of water supplied for caisson cooling is established.