Final temperature of ventilation air heating in multi-row mine calorifier units

Authors:
L. P. Severin
K. A. Dolgov
Date submitted:
1972-07-12
Date accepted:
1972-09-27
Date published:
1973-01-01

Abstract

It is known that at the vast majority of mines and mines located in areas with harsh climate, in winter time part of the atmospheric air supplied to underground workings for their ventilation is heated. To do this at the shafts and adits, where the ventilation jet comes, build, as a rule, steam caloriferous installations with a multi-row arrangement of metal plate calorifiers, the sequential movement of heated air in them provides the necessary air temperature difference...

Область исследования:
(Archived) Without section
Go to volume 65

Similar articles

Determination of efficiency of electro-hydraulic drive of mining machines feed drive
1973 A. F. Lorenzo, V. S. Nenashin
Some results of studying the operational reliability of heavy-duty dump trucks in severe climatic conditions
1973 A. A. Kuleshov, A. I. Talko
Investigation of the process of hydraulic mixtures thickening
1973 Yu. P. Boytsov
Stress-strain state of elastic half-space loaded by external jet pressure
1973 K. G. Asatur
Comparison of connection schemes of underground hydraulic monitors in a coal mine section
1973 A. B. Nezametdinov
Principles of construction of automated control systems of railway transportation for schemes with one assembly station
1973 L. G. Tymovsky, I. I. Margolin