Adjustable main drive system for coal shearers using the DFC-IM (Direct Frequency Converter - Induction Motor) configuration
Abstract
The increase in labour productivity in mines and the improvement of miners' working conditions have led to the widespread implementation of mining complexes with coal-cutting machines. To ensure high operational efficiency under various conditions, coal-cutting machines must incorporate regulation of both feed and cutting speeds. ...
Область исследования:
(Archived) Without section
References
- Dokukin A.V., Krasnikov Yu.D., Khurgin Z.Ya. Dynamic processes in mining machines. M., Nauka, 1972.
- Kitaenko G.I. Marine electric power systems with enhanced parameters. L., Sudostroenie, 1970.
- Kozyaruk A.E. Frequency converter reliability issues. PH LDNTP, 1968.
- Pavlov Yu.P. Thyristor direct frequency converter with forced commutation. PH LDNTP, 1973.
Similar articles
Control of a thyristor converter for a synchronous motor in main ventilation fan drives
1976 V. N. Yazev
Study of capacitor braking of squirrel-cage induction motors using an analogue computer
1976 O. V. Ivanov, B. I. Komarov
Asynchronous motor with series capacitors under periodic loading
1976 O. V. Ivanov, B. I. Komarov, A. D. Sigarreta