Asynchronous motor with series capacitors under periodic loading
Abstract
The loads of mining machine drives are characterised by significant irregularity and, as correlation analysis of the operating modes of extraction and tunnelling combines demonstrates, contain periodic components with a frequency range of 0.5–20 Hz. In extensive mine networks, cutter-loader electric motors often cannot stably sustain a load equal to their rated power. ...
Область исследования:
(Archived) Without section
References
- х Glushko V.V. Operating mode characteristics of mining machines and their automatic control. M., Nedra, 1973.
- хх Ivanov O.V., Kvyatkovsky V.M., Komarov B.I. Study of self-oscillation in induction motors within networks featuring series capacitors. - Electricity, 1969, No. 3.