The reduction of the corrosion rate of the zinc anode of the chemical current source (CPS) through the use of inhibitors effectively replacing mercury was investigated. The greatest effect was obtained when alloying zinc alloy with Pb and Cd in combination with an organic inhibitor introduced into the electrolyte.