Determination of the grid impedance in power consumption modes with harmonics

Article preview

The paper investigates the harmonic impedance determination of the power supply system of a mining enterprise. This parameter is important when calculating modes with voltage distortions, since the determined parameters of harmonic currents and voltages significantly depend on its value, which allow the most accurate modeling of processes in the presence of distortions in voltage and current. The power supply system of subsurface mining is considered, which is characterized by a significant branching of the electrical network and the presence of powerful nonlinear loads leading to a decrease in the power quality at a production site. The modernization of the mining process, the integration of automated electrical drive systems, renewable energy sources, energy-saving technologies lead to an increase in the energy efficiency of production, but also to a decrease in the power quality, in particular, to an increase in the level of voltage harmonics. The problem of determining the grid harmonic impedance is solved in order to improve the quality of design and operation of power supply systems for mining enterprises, taking into account the peculiarities of their workload in the extraction of solid minerals by underground method. The paper considers the possibility of determining the grid impedance based on the measurement of non-characteristic harmonics generated by a special nonlinear load. A thyristor power controller based on phase regulation of the output voltage is considered as such a load. Simulation computer modeling and experimental studies on a laboratory test bench are used to confirm the proposed method. The recommendations for selecting load parameters and measuring device connection nodes have been developed.

How to cite: Skamyin A.N., Dobush V.S., Jopri M.H. Determination of the grid impedance in power consumption modes with harmonics // Journal of Mining Institute. 2023. Vol. 261 . p. 443-454. DOI: 10.31897/PMI.2023.25
Electromechanics and mechanical engineering
  • Date submitted
    2021-01-20
  • Date accepted
    2021-03-15
  • Date published
    2021-04-26

Improving the quality of electricity in the power supply systems of the mineral resource complex with hybrid filter-compensating devices

Article preview

The urgency and necessity of choosing and justifying the structures of hybrid filter-compensating devices based on series and parallel active filters to improve the quality of electricity in the power supply systems of enterprises of the mineral resource complex is shown. Mathematical models of hybrid filter compensating devices based on parallel and series active filters have been developed. Based on these mathematical models, computer simulation models of the indicated hybrid structures have been developed. The results of simulation showed the effectiveness of the correction of power quality indicators in terms of reducing the level of higher harmonics of current and voltage, as well as voltage deviations. The degree of influence of filter-compensating devices on the power quality indicators, which determine the continuity and stability of the technological process at the enterprises of the mineral resource complex, have been revealed. It has been established that a hybrid filter-compensating device based on a parallel active filter can reduce the level of higher harmonics of current and voltage by more than 90 and 70 %, respectively, and based on a series active filter, it can reduce the level of higher harmonics of voltage by more than 80 %. Based on the simulation results, the possibility of compensating for the reactive power of a hybrid structure based on parallel active and passive filters has been revealed. The possibility of integrating hybrid filter-compensating devices into more complex multifunctional electrical systems for the automated improvement of the quality of electricity is substantiated, as well as the expediency and prospects of their use in combined power supply systems based on the parallel operation of centralized and autonomous sources of distributed generation.

How to cite: Sychev Y.A., Zimin R.Y. Improving the quality of electricity in the power supply systems of the mineral resource complex with hybrid filter-compensating devices // Journal of Mining Institute. 2021. Vol. 247 . p. 132-140. DOI: 10.31897/PMI.2021.1.14
Electromechanics and mechanical engineering
  • Date submitted
    2018-12-25
  • Date accepted
    2019-03-02
  • Date published
    2019-06-25

Non-linear electrical load location identification

Article preview

The article discusses the issues of identifying the location of non-linear loads in electrical networks which makes the main contribution to the distortion of the non-sinusoidal voltage and current in the distribution network of an industrial enterprise, including mining enterprises. The existing methods for determining the location of the source of higher harmonic components in voltage and current are considered, their advantages and disadvantages are revealed. The main disadvantages of the methods used include the low accuracy and incorrectness of their use in existing enterprises. When developing a new method, the authors were faced with the task of simplicity of its use in the conditions of industrial operation of electrical equipment and the absolute correctness of the results obtained. The proposed method of identifying the source of higher harmonics is based on the variation of the parameters of the power system, in particular, the change in resistance of power transformers taking into account their transformation ratio. It is shown that by varying the transformation ratio during regulation under load, the total coefficient of the harmonic components of the voltage changes. Based on the constructed dependencies, the variation of the derivative of this function with different variations of the parameters of sources of higher harmonics is analyzed and a method is developed that allows determining the share contribution of consumers to the total harmonic component of the voltage.

How to cite: Pirog S., Shklyarskiy Y.E., Skamyin A.N. Non-linear electrical load location identification // Journal of Mining Institute. 2019. Vol. 237 . p. 317-321. DOI: 10.31897/PMI.2019.3.317
Mining machine, electrical engineering and electromechanics
  • Date submitted
    2010-07-29
  • Date accepted
    2010-09-27
  • Date published
    2011-03-21

Efficiency increasing of condenser batteries operation in mining enterprise`s electric circuits

Article preview

This work contains the method of effective reactive power compensation at the expense of high harmonics reduction. The decrease of condenser batteries overloading from the high harmonics is based on variation of condenser power depending on current and voltage spectral structure, electric network parameters and load power.

How to cite: Skamin A.N. Efficiency increasing of condenser batteries operation in mining enterprise`s electric circuits // Journal of Mining Institute. 2011. Vol. 189 . p. 107-110.
Mining machine, electrical engineering and electromechanics
  • Date submitted
    2010-07-10
  • Date accepted
    2010-09-15
  • Date published
    2011-03-21

Reduction methods of high harmonics influence on the electric equipment operation

Article preview

This work contains brief analysis of high harmonics reduction methods. It is offered to make a choice between reduction methods of high harmonics influence on condenser batteries depending on factors of harmonics occurrence. Definition algorithm for the most effective method of high harmonics reduction on condenser batteries operation is created.

How to cite: Shklyarsky Y.E., Skamin A.N. Reduction methods of high harmonics influence on the electric equipment operation // Journal of Mining Institute. 2011. Vol. 189 . p. 121-124.