Submit an Article
Become a reviewer
Vol 138
Pages:
23-28
Download volume:
RUS
Article

Calculation of connections with guaranteed interference fit for a given probability of failure-free operation

Authors:
E. S. Kuznetsov
Date submitted:
1992-09-13
Date accepted:
1992-11-20
Date published:
1993-12-28

Abstract

Cylindrical and tapered surfaces can be joined by means of interference fit. This type of mating of parts is called a guaranteed interference fit. It is characterized by simplicity and manufacturability, possibility of application in mass production, good mutual centering of parts and load distribution over the entire seating surface.