Analysis of electromechanical coupling in electric drive by asynchronous valve cascade system of mine hoisting unit
Authors:
About authors
- Perm State Technical University
Abstract
The paper focuses on the research methodology of electromechanical system with elastic coupling of the mine hoisting unit and electric drive according to the asynchronous valve cascade system. An analysis of dynamic properties and electromechanical coupling as applied to the skip hoisting unit equipped with an electric drive based on the asynchronous valve cascade system is carried out. An expression for determining the electromechanical coupling coefficient is obtained and the results are given for a particular installation.
References
- Ключев В.И. Ограничение динамических характеристик нагрузок электропривода. М.: Энергия, 1971.
- Католиков В.Е. Динамические режимы рудничного подъема / В.Е.Католиков, А.Д.Динкель. М.: Недра, 1995.
Similar articles
Experimental determination of the contact thermal resistance of steel pipes with rolled and L-shaped wound aluminum alloy fins
2003 K. B. Semenido