Determination of optimal stack sizes of a half-bunker warehouse

Authors:
I. I. Margolin
A. M. Faktorovich
Date submitted:
1972-07-18
Date accepted:
1972-09-24
Date published:
1973-01-01

Abstract

Semi hopper storage with slotted outlet is a type of modern automated large-capacity storage. The criterion for selecting the main parameters can be taken as a minimum cost of construction of the warehouse, since the change in the length L and cross-section F of the stack has a relatively small effect on the operating costs.