Expansion of limits and increase of measurement accuracy of high-frequency moisture meters on the basis of E12-1A type capacitance meter

Authors:
E. A. Kalm
V. G. Valeev
Date submitted:
1974-07-12
Date accepted:
1974-09-14
Date published:
1975-01-01

Abstract

At discrete express control of moisture dispersed materials in some cases use devices made on the basis of the device E12-1A, a simplified scheme of which is shown in Figure 1. ...