Submit an Article
Become a reviewer
Vol 105
Pages:
103-107
Download volume:
RUS
Article

Results of field tests of the high-frequency thermo-drilling complex TBS-112 HF while drilling a deep borehole in a low-temperature glacier cover (Vostok Station).

Authors:
E. A. Zagrivny
Date submitted:
1984-09-23
Date accepted:
1984-11-05
Date published:
1985-11-27

Abstract

Vostok station is located in Central Antarctica in the area of the South Geomagnetic Pole in 1410 km from Mirny Observatory. The peculiarities of Vostok station are extremely low on Earth temperatures (-89 °С) and atmospheric pressure (405-480 mm Hg), significant elevation above sea level (3488 m).