Submit an Article
Become a reviewer
Yu. P. Pavlov
Yu. P. Pavlov

Co-authors

Articles

Article
  • Date submitted
    1987-09-30
  • Date accepted
    1987-11-22

Asynchronous electric drive with transformer- thyristor voltage regulator

Article preview

Electric drives of escalators of subways are in the same row with the rolling stock by their purpose.

How to cite: Klimash V.S., Soloviev V.S., Pavlov Y.P., Nekrasov V.V. Asynchronous electric drive with transformer- thyristor voltage regulator // Journal of Mining Institute. 1988. Vol. 117. p. 89-92.
Article
  • Date submitted
    1978-08-16
  • Date accepted
    1978-10-15

Control units of thyristor frequency converter in vector control system

Article preview

Power thyristor inverter control unit BUI must provide control of the frequency and phase of the output voltage of the autonomous inverter thyristor frequency converter THR using two input three-phase voltage systems. For this purpose, at the output of the unit, must be formed long pulses of control of the inverter thyristors, necessary for a stable and reliable start of the drive ...

How to cite: Alekseev V.V., Dartau V.A., Pavlov Y.P., Rudakov V.V. Control units of thyristor frequency converter in vector control system // Journal of Mining Institute. 1979. Vol. 84. p. 113-119.
Article
  • Date submitted
    1975-07-02
  • Date accepted
    1975-09-19

Principles of constructing control systems for thyristor frequency converters in drives with block vector regulation

Article preview

When employing thyristor frequency converters (TFCs) in block control systems of AC variable frequency drives, the converter is controlled by a two-phase AC signal modulated in magnitude, frequency, and phase. …

How to cite: Pavlov Y.P. Principles of constructing control systems for thyristor frequency converters in drives with block vector regulation // Journal of Mining Institute. 1976. Vol. 70. Iss. 1. p. 55-60.
Article
  • Date submitted
    1975-07-28
  • Date accepted
    1975-09-18

Control of direct frequency conversions from AC signals in block vector regulation systems for induction drives

Article preview

Based on the principle of output voltage formation, direct frequency converters are divided into two main types: thyristor-based direct frequency converters with natural commutation (DFC-NC) and thyristor-based direct frequency converters with forced commutation (DFC-FC). In DFC-NC, the output frequency is formed through natural commutation within a half-cycle of the output voltage. ...

How to cite: Dartau V.A., Pavlov Y.P., Smirnov E.M., Yazev V.N. Control of direct frequency conversions from AC signals in block vector regulation systems for induction drives // Journal of Mining Institute. 1976. Vol. 70. Iss. 1. p. 61-67.
Article
  • Date submitted
    1975-07-13
  • Date accepted
    1975-09-02

Energy characteristics of the frequency converter–motor system in frequency-controlled drives of mining machinery

Article preview

For the analysis of the spectral composition of the output voltage in the previously proposed thyristor-based direct frequency converter with forced commutation (DFC-FC), we shall employ the following expression…

How to cite: Pavlov Y.P., Kozyaruk A.E., Kulagin N.S., Solovev V.S. Energy characteristics of the frequency converter–motor system in frequency-controlled drives of mining machinery // Journal of Mining Institute. 1976. Vol. 70. Iss. 1. p. 68-76.
Article
  • Date submitted
    1975-07-20
  • Date accepted
    1975-09-17

Adjustable main drive system for coal shearers using the DFC-IM (Direct Frequency Converter - Induction Motor) configuration

Article preview

The increase in labour productivity in mines and the improvement of miners' working conditions have led to the widespread implementation of mining complexes with coal-cutting machines. To ensure high operational efficiency under various conditions, coal-cutting machines must incorporate regulation of both feed and cutting speeds. ...

How to cite: Pavlov Y.P., Rudakov V.V., Solovev V.S., Grinberg Y.P. Adjustable main drive system for coal shearers using the DFC-IM (Direct Frequency Converter - Induction Motor) configuration // Journal of Mining Institute. 1976. Vol. 70. Iss. 1. p. 84-91.