It is possible to consider as an optimum behavior of operation a mode providing the least daily allowance or annual charges of the electric power. Such mode can be received by increase in efficiency up to maximal and reduction of losses of a pressure in pipelines. On design stage the optimum behaviour can be achieved with the help of an offered design procedure of modes of operation of miner pump installation.