<?xml version="1.0" encoding="UTF-8"?>
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.4" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="issn">2411-3336</journal-id>
      <journal-id journal-id-type="eissn">2541-9404</journal-id>
      <journal-title-group>
        <journal-title xml:lang="ru">Записки Горного института</journal-title>
        <journal-title xml:lang="en">Journal of Mining Institute</journal-title>
      </journal-title-group>
      <publisher>
        <publisher-name xml:lang="ru">Санкт-Петербургский горный университет императрицы Екатерины ΙΙ</publisher-name>
        <publisher-name xml:lang="en">Empress Catherine II Saint Petersburg Mining University</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id custom-type="pmi" pub-id-type="custom">pmi-7211</article-id>
      <article-id pub-id-type="uri">https://pmi.spmi.ru/pmi/article/view/7211</article-id>
      <article-categories>
        <subj-group subj-group-type="section-heading" xml:lang="ru">
          <subject>Электропривод, электроснабжение, автоматика и управление горного и нефтегазового производств</subject>
        </subj-group>
        <subj-group subj-group-type="section-heading" xml:lang="en">
          <subject>Electric drive, power supply, automation and control of mining and oil and gas production</subject>
        </subj-group>
      </article-categories>
      <title-group>
        <article-title xml:lang="en">Relevance of application of centralized protection with inverse dependent time-current characteristic of RXIDG type for networks with resistive neutral groundi</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Актуальность применения централизованной защиты с обратнозависимой времятоковой характеристикой вида RXIDG для сетей с резистивным заземлением нейтрали</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes">
          <name name-style="eastern">
            <surname>Bychin</surname>
            <given-names>M. A.</given-names>
          </name>
          <name-alternatives>
            <name name-style="eastern" xml:lang="ru">
              <surname>Бычин</surname>
              <given-names>М. А.</given-names>
            </name>
            <name name-style="western" xml:lang="en">
              <surname>Bychin</surname>
              <given-names>M. A.</given-names>
            </name>
          </name-alternatives>
          <email>pmi@spmi.ru</email>
          <xref ref-type="aff" rid="aff1"/>
        </contrib>
        <aff-alternatives id="aff1">
          <aff>
            <institution xml:lang="ru">Санкт-Петербургский государственный горный институт (технический университет) (Россия)</institution>
          </aff>
          <aff>
            <institution xml:lang="en">G.V. Plekhanov Saint Petersburg Mining Institute (Russia)</institution>
          </aff>
        </aff-alternatives>
      </contrib-group>
      <pub-date pub-type="epub" iso-8601-date="2008-11-18">
        <day>18</day>
        <month>11</month>
        <year>2008</year>
      </pub-date>
      <pub-date date-type="collection">
        <year>2008</year>
      </pub-date>
      <volume>178</volume>
      <fpage>126</fpage>
      <lpage>129</lpage>
      <history>
        <date date-type="received" iso-8601-date="2007-11-18">
          <day>18</day>
          <month>11</month>
          <year>2007</year>
        </date>
        <date date-type="accepted" iso-8601-date="2008-01-24">
          <day>24</day>
          <month>01</month>
          <year>2008</year>
        </date>
        <date date-type="rev-recd" iso-8601-date="2008-11-18">
          <day>18</day>
          <month>11</month>
          <year>2008</year>
        </date>
      </history>
      <permissions>
        <copyright-statement xml:lang="ru">© 2008 М. А. Бычин</copyright-statement>
        <copyright-statement xml:lang="en">© 2008 M. A. Bychin</copyright-statement>
        <copyright-year>2008</copyright-year>
        <copyright-holder xml:lang="ru">М. А. Бычин</copyright-holder>
        <copyright-holder xml:lang="en">M. A. Bychin</copyright-holder>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0" xml:lang="ru">
          <license-p>Эта статья доступна по лицензии Creative Commons Attribution 4.0 International (CC BY 4.0)</license-p>
        </license>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0" xml:lang="en">
          <license-p>This article is licensed under a Creative Commons Attribution 4.0 International License (CC BY 4.0)</license-p>
        </license>
      </permissions>
      <self-uri xlink:type="simple" xlink:href="https://pmi.spmi.ru/pmi/article/view/7211">https://pmi.spmi.ru/pmi/article/view/7211</self-uri>
      <abstract xml:lang="ru">
        <p>В связи с требованиями ограничения перенапряжений в сетях напряжением 6-35 кВ с резистивным заземлением нейтрали до соответствующих значений возникает необходимость применения достаточно высокоомных резисторов, использование которых делает неэффективным применение традиционных защит от однофазных замыканий на землю, основанных на токовом принципе. Предложено использовать специальные токовые характеристики вида RXIDG, реализуемые на цифровых реле. Для защит выполнена оценка чувствительности и рассмотрены области применения обратнозависимых характеристик в зависимости от параметров сети. Показана актуальность применения данных устройств защиты, использующих нелинейные токовые характеристики, при грамотной настройке для защиты сетей 6-35 кВ с достаточно высокоомным заземлением нейтрали от однофазных замыканий на землю.</p>
      </abstract>
      <abstract xml:lang="en">
        <p>It is necessary to use considerably highomed resisters because of there are requirements to restrict over voltage by voltage 6-35 kilovolts with the resistive ground neutral to the same meaning in the networks. It makes usage of traditional protection from ground short circuit based on a current curve principle is inefficacious. Special characteristics of current curve the type RXIDG realized on digital relay are offered to use for these purposes. For these protections valuation of sensibility was done and the fields of using for opposite dependence characteristics in dependence on dimensions of networks was viewed. There is necessity for these devices of protections nonlinear characteristic of current curve under perfect tooling for protection of the networks 6-35 kilovolts considerably highomed ground neutral ground short circuit in the article.</p>
      </abstract>
    </article-meta>
  </front>
  <body/>
  <back>
    <ref-list>
      <ref id="ref1">
        <label>1</label>
        <mixed-citation xml:lang="ru">Виштибеев А.В. О длительности работы резистора для заземления нейтрали в электрических сетях 6-35 кВ / А.В.Виштибеев, Н.И.Емельянов, М.В.Ильиных, Л.И.Сарин; Труды Второй всероссийской научно-технической конференции «Ограничение перенапряжений и режимы заземления нейтрали сетей 6-35 кВ». Новосибирск, 2002.</mixed-citation>
      </ref>
      <ref id="ref2">
        <label>2</label>
        <mixed-citation xml:lang="ru">Евдокунин Г.А. Выбор способа заземления нейтрали в сетях 6-10 кВ / Г.А.Евдокунин, С.В.Гудилин, А.А.Корепанов // Электричество. 1998. № 12. С.8-22.</mixed-citation>
      </ref>
      <ref id="ref3">
        <label>3</label>
        <mixed-citation xml:lang="ru">Титенков С.C. Четыре режима заземления нейтрали в сетях 6-35 кВ. Изолированную нейтраль объявим вне закона // Новости электротехники. 2003. № 5.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>