<?xml version="1.0" encoding="UTF-8"?>
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.4" article-type="research-article">
  <front>
    <journal-meta>
      <journal-id journal-id-type="issn">2411-3336</journal-id>
      <journal-id journal-id-type="eissn">2541-9404</journal-id>
      <journal-title-group>
        <journal-title xml:lang="ru">Записки Горного института</journal-title>
        <journal-title xml:lang="en">Journal of Mining Institute</journal-title>
      </journal-title-group>
      <publisher>
        <publisher-name xml:lang="ru">Санкт-Петербургский горный университет императрицы Екатерины ΙΙ</publisher-name>
        <publisher-name xml:lang="en">Empress Catherine II Saint Petersburg Mining University</publisher-name>
      </publisher>
    </journal-meta>
    <article-meta>
      <article-id custom-type="pmi" pub-id-type="custom">pmi-12682</article-id>
      <article-id pub-id-type="uri">https://pmi.spmi.ru/pmi/article/view/12682</article-id>
      <article-categories/>
      <title-group>
        <article-title xml:lang="en">Power transformer with sub-magnetization for regulation and control of asynchronous electric drive of mine hoist</article-title>
        <trans-title-group xml:lang="ru">
          <trans-title>Силовой трансформатор с подмагничиванием для регулирования и управления асинхронным электроприводом рудничного подъема</trans-title>
        </trans-title-group>
      </title-group>
      <contrib-group>
        <contrib contrib-type="author" corresp="yes">
          <name name-style="eastern">
            <surname>Alatortsev</surname>
            <given-names>S. A.</given-names>
          </name>
          <name-alternatives>
            <name name-style="eastern" xml:lang="ru">
              <surname>Алаторцев</surname>
              <given-names>С. А.</given-names>
            </name>
            <name name-style="western" xml:lang="en">
              <surname>Alatortsev</surname>
              <given-names>S. A.</given-names>
            </name>
          </name-alternatives>
          <email>pmi@spmi.ru</email>
          <xref ref-type="aff" rid="aff1"/>
        </contrib>
        <aff-alternatives id="aff1">
          <aff>
            <institution xml:lang="ru"/>
          </aff>
          <aff>
            <institution xml:lang="en"/>
          </aff>
        </aff-alternatives>
        <contrib contrib-type="author">
          <name name-style="eastern">
            <surname>Shen-gu</surname>
            <given-names>Gu </given-names>
          </name>
          <name-alternatives>
            <name name-style="eastern" xml:lang="ru">
              <surname>Шэн-гу</surname>
              <given-names>Гу </given-names>
            </name>
            <name name-style="western" xml:lang="en">
              <surname>Shen-gu</surname>
              <given-names>Gu </given-names>
            </name>
          </name-alternatives>
          <email>pmi@spmi.ru</email>
          <xref ref-type="aff" rid="aff2"/>
        </contrib>
        <aff-alternatives id="aff2">
          <aff>
            <institution xml:lang="ru"/>
          </aff>
          <aff>
            <institution xml:lang="en"/>
          </aff>
        </aff-alternatives>
      </contrib-group>
      <pub-date pub-type="epub" iso-8601-date="1961-05-06">
        <day>06</day>
        <month>05</month>
        <year>1961</year>
      </pub-date>
      <pub-date date-type="collection">
        <year>1961</year>
      </pub-date>
      <volume>45</volume>
      <issue>1</issue>
      <fpage>26</fpage>
      <lpage>31</lpage>
      <history>
        <date date-type="received" iso-8601-date="1960-07-26">
          <day>26</day>
          <month>07</month>
          <year>1960</year>
        </date>
        <date date-type="accepted" iso-8601-date="1960-09-16">
          <day>16</day>
          <month>09</month>
          <year>1960</year>
        </date>
        <date date-type="rev-recd" iso-8601-date="1961-05-06">
          <day>06</day>
          <month>05</month>
          <year>1961</year>
        </date>
      </history>
      <permissions>
        <copyright-statement xml:lang="ru">© 1961 С. А. Алаторцев, Гу  Шэн-гу</copyright-statement>
        <copyright-statement xml:lang="en">© 1961 S. A. Alatortsev, Gu  Shen-gu</copyright-statement>
        <copyright-year>1961</copyright-year>
        <copyright-holder xml:lang="ru">С. А. Алаторцев, Гу  Шэн-гу</copyright-holder>
        <copyright-holder xml:lang="en">S. A. Alatortsev, Gu  Shen-gu</copyright-holder>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0" xml:lang="ru">
          <license-p>Эта статья доступна по лицензии Creative Commons Attribution 4.0 International (CC BY 4.0)</license-p>
        </license>
        <license license-type="open-access" xlink:href="http://creativecommons.org/licenses/by/4.0" xml:lang="en">
          <license-p>This article is licensed under a Creative Commons Attribution 4.0 International License (CC BY 4.0)</license-p>
        </license>
      </permissions>
      <self-uri xlink:type="simple" xlink:href="https://pmi.spmi.ru/pmi/article/view/12682">https://pmi.spmi.ru/pmi/article/view/12682</self-uri>
      <abstract xml:lang="ru">
        <p>Силовой трехфазный трансформатор с плавным регулированием напряжения под нагрузкой имеет общий магнитопровод М с под­разделением на девять стержней, расположенных в одной плоскости. Три основных стержня 2, 5 и 8 ис­пользуются для намотки пер­вичных фазных обмоток Wi . На шести добавочных стерж­нях 1, 3, 4, 6, 7 я 9 размещены обмотки подмагничивания по­стоянным током Wд. Вторич­ные фазные обмотки W2 распо­ложены на девяти стержнях: три на основных 2, 5, 8 и но две на добавочных 1, 3, 4, 6, 7 и 9. Компенсационная обмотка Wk наматывается на все доба­вочные стержни. Глубокое плавное регулирование вторич­ного напряжения трансформа­тора осуществляется измене­нием величины постоянного то­ка в шести обмотках подмагни­чивания Wд.</p>
      </abstract>
      <abstract xml:lang="en">
        <p>A power three-phase transformer with stepless voltage regulation under load has a common magnetocoupler M with subdivision into nine rods arranged in the same plane. The three main rods 2, 5 and 8 are used for winding the primary phase windings Wi . The six additive rods 1, 3, 4, 6, 7 and 9 house the DC magnetizing windings Wd. Secondary phase windings W2 are located on nine rods: three on the main rods 2, 5, 8 and two on additive rods 1, 3, 4, 6, 7 and 9. The compensating winding WK is wound on all the additive rods. Deep smooth regulation of the secondary voltage of the transformer is carried out by changing the value of the DC current in the six windings of the sub-magnetizing winding Wd.</p>
      </abstract>
    </article-meta>
  </front>
  <body/>
  <back>
    <ref-list>
      <ref id="ref1">
        <label>1</label>
        <mixed-citation xml:lang="ru">Бамдас А. М., Сомов В. А., Шмидт Д. Т. Трансформаторы и стабилизаторы, регулируемые подмагничиванием шунтов. Госэнергоиздат, 1959.</mixed-citation>
        <mixed-citation xml:lang="en">Bamdas A. M., Somov V. A., Schmidt D. T. Transformers and stabilizers regulated by shunt magnetization. Gosenergoizdat, 1959.</mixed-citation>
      </ref>
      <ref id="ref2">
        <label>2</label>
        <mixed-citation xml:lang="ru">Гу Шэн-гу и Сучков В. А. Трехфазный трансформатор с плавным регулированием напряжения под нагрузкой. Тр. Горьковского политехн. ин-та, 1959, т. XV, вып. 4.</mixed-citation>
        <mixed-citation xml:lang="en">Gu Sheng-gu and Suchkov V. A. Three-phase transformer with smooth voltage regulation under load. Proc. Gorky Polytechnic Institute, 1959, vol. XV, iss. 4.</mixed-citation>
      </ref>
      <ref id="ref3">
        <label>3</label>
        <mixed-citation xml:lang="ru">Бамдас А. М., Сучков В. А. и Гу Шэн-гу. Трехфазный трансформатор с плавным бесконтактным регулированием напряжения под нагрузкой. «Вестник электропромышленности АН КНР», 1959, № 10.</mixed-citation>
        <mixed-citation xml:lang="en">Bamdas, A. M., Suchkov, V. A. and Gu Sheng-gu. Three-phase transformer with smooth non-contact voltage regulation under load. Bulletin of Electrical Industry of the Academy of Sciences of the People's Republic of China, 1959, No. 10.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>
